Installation
Multiple Device Protection:
Note: The maximum distance between any two In-Line 10G Network
Surge Protectors is 240 ft. (73 m).
1. Disconnect the installed patch cables from both of the devices
you wish to protect.
2. Connect a B110-SP-10G to each end of the previously
uninstalled patch cable, ensuring both ends of the patch cable
are connected to the "Cable End."
3. With user-supplied Cat5/5e/6/6a/8 patch cables, connect the
"Equipment End" of each Surge Protector to the network devices
you wish to protect.
Note: For best protection performance, the Cat5/5e/6/6a/8 patch
cable between the "Equipment End" of the B110-SP-10G and
the network equipment to be protected should not exceed 240 ft.
(73 m). Tripp Lite's N261-Series Cat6a Snagless Patch Cables are
recommended.
4. Connect the ground wire to each In-Line 10G Network Surge
Protector and then to earth ground.