Programming the interface through the Easy base unit (code GW 90 831).
Each programming channel is selected from the menu channel list, "Application → New
Function" or "Application → Edit function"
Names of the functions on the Easy base unit
edges
button
scenes
The functions can be created after the devices have been selected.
Refer to the Easy base unit documentation for further information on the programming
procedures.
HOW TO IDENTIFY INTERFACE CHANNELS ON THE EASY BASE UNIT
To identify the device number and find the channels in the menu "New function" press
the programming button for more than 2 seconds. The first channel will be selected
"A.Switch.act.X.1"
Interface channels are displayed on the base unit as follows
where "X" identifies the number of the device automatically linked to the Easy base unit.
The functions associated with each channel are described in the paragraph on Easy
Functions.
PROGRAMMING
for all functions associated with channels 1..5 when
controlled by the GW 10 752 push-button panel or interface
contacts GW 90 834
for all functions associated with channels 1..5 when
controlled by the GW 10 752 push-button panel or interface
contacts GW 90 834
scene management (in association with channel 6)
Channel
Base unit display
1
A.Switch.act. X.1
2
A.Switch.act. X.2
3
A.Switch.act. X.3
4
A.Switch.act. X.4
5
A.Switch.act. X.5
6
A.Switch.act. X.6