Adjust the RSL 400 safety laser scanner horizontally and vertically.
You can find information on the correct alignment of the RSL 400 in the oper-
ating instructions of the RSL 400 or at www.leuze.com.
Ä
Fasten the screws in the desired end position.
ð
Mounting system and RSL 400 are mounted on the floor stand.
Height adjustment
To adjust the scanning height of the RSL 400 on the floor stand, you need a
13 mm (M8) torque wrench.
Ä
Loosen the fastening screws of the cover and of the side guard.
Ä
Remove the cover and the side guard.
Ä
Loosen the screws for the RSL mounting bracket.
Ä
Align the RSL 400 at the desired position. The notches on the floor stand are
used to align the RSL mounting bracket with respect to the scanning height.
RSL 400 PROFIsafe
model
RSL 4xxP with
CU400P-3M12
RSL 4xxP with
CU400P-AIDA
Ä
Screw the RSL mounting bracket to the floor stand at the desired height.
Ä
Screw the side guard to the outside of the RSL mounting bracket at the same
height as the RSL 400.
Ä
Guide the cover into the floor stand at the desired height and fasten the cover
from the outside through the stand with four M8 x 20 screws.
ð
Tightening torque for the M8 x 20 screws: 25 Nm
Technical data
BTF815-30M floor stand
Part no.
Description
To be used with BTU800M mounting
system (part no. 53800130)
Weight
Dimensions
10
Scanning height 150 mm
3
Normal mounting
Lower edge of RSL mount-
ing bracket aligned with
lower notch
Upside-down mounting
Upper edge of RSL mount-
ing bracket aligned with up-
per notch
53800138
Mounting bracket for floor mounting, ad-
justable scanning height
18 kg
See
4
Scanning height 300 mm
2
Normal mounting
Upper edge of RSL mount-
ing bracket aligned with up-
per notch
Normal mounting
Upper edge of RSL mount-
ing bracket aligned with up-
per notch