7.2. DIELECTRIC STRENGTH
Primary to Frame Ground : 1800Vac for 1 sec.
Primary to Secondary : 1800Vac for 1 sec
7.3. INSULATION RESISTANCE
Primary to Frame Ground : 20M ohm , Minimum
Primary to Secondary : 20M ohm , Minimum
8. RELIABILITY
8.1. RELIABILITY
The power supply reliability, When calculated by MIL-HDBK-217;latest revision, are exceed 100,000 hours with all output
at maximum load and an ambient temperature of 25 ℃ .
9. LABELLING
Label marking will be permanent, legible and complied with all agency requirements.
9.1. MODEL NUMBER LABEL
Labels will be affixed to the sides of the power supply showing the following:
- Manufacturer 's name and logo.
- Model no., serial no., revision level, location of manufacturer.
- The total power output and the maximum load for each output.
- AC input rating.
10. MECHANICAL SPECIFICATIONS
The mechanical drawing of the subject power supply, which indicate the form factor, location of The mounting holes,
location, the length of the connectors, and other physical specifications of the subject power supply. Please refer to the
attachment drawing.
11. POWER SUPPLY CONNECTOR OVERUSE DEFINITION
All manuals and user guides at all-guides.com
8