Impact speed
Ambient temperature for operation
Storage temperature
4.1
Battery
Battery operating voltage
Ambient temperature for operation
Storage temperature
Battery charging starting temperature
4.2
Accessory tools – permissible diameters
Ø range of keyless chuck
Ø range of keyless chuck
Ø wood drill bits (hardwood)
Ø wood drill bits (hardwood)
Ø wood drill bits (softwood)
Ø wood drill bits (softwood)
Ø drill bits for metal
Ø drill bits for metal
Ø drilling in concrete/masonry (hammer-action drilling)
Ø drilling in concrete/masonry (hammer-action drilling)
5
Operation
5.1
Inserting the battery
WARNING
Risk of injury by short circuit or falling battery!
▶ Before inserting the battery, make sure that the contacts on the battery and the contacts on the product
are free of foreign matter.
▶ Make sure that the battery always engages correctly.
1. Charge the battery fully before using it for the first time.
2. Push the battery into the product until it engages with an audible click.
3. Check that the battery is seated securely.
5.2
Removing the battery
1. Press the battery release buttons.
2. Remove the battery from the tool.
5.3
Charging the battery
1. Before charging the battery, read the operating instructions for the charger.
2. Make sure that the contacts on the battery and the contacts on the charger are clean and dry.
3. Use an approved charger to charge the battery. → page 6
*2231427*
SF 6-A22
•/•
1 ℉ ... 140 ℉
(−17 ℃ ... 60 ℃)
−4 ℉ ... 158 ℉
(−20 ℃ ... 70 ℃)
2231427
SF 6H-A22
36,000 /min
1 ℉ ... 140 ℉
(−17 ℃ ... 60 ℃)
−4 ℉ ... 158 ℉
(−20 ℃ ... 70 ℃)
21.6 V
1 ℉ ... 140 ℉
(−17 ℃ ... 60 ℃)
−4 ℉ ... 104 ℉
(−20 ℃ ... 40 ℃)
14 ℉ ... 113 ℉
(−10 ℃ ... 45 ℃)
1/16 in ... 1/2 in
1.5 mm ... 13 mm
1/16 in ... 3/4 in
1.5 mm ... 20 mm
1/16 in ... 1 1/4 in
1.5 mm ... 32 mm
1/16 in ... 1/2 in
1.5 mm ... 13 mm
5/32 in ... 1/2 in
4 mm ... 12 mm
English