16
ENGLISH
8. Operation
LED indicators
Input Voltage Level LED
Output Load Level LED
Status LED
LED status
Red
Orange
Green
Orange
Red
LED status
Green
Orange
Red
Led indication
Green
Red (+ audible beep)
DC 12 V
DC 24V
< 11.0 V
< 22.0 V
11.0 ~ 11.5 V
22.0 ~ 23.0 V
11.5 ~ 15.0 V
23.0 ~ 30.0 V
15.0 ~ 15.5 V
30.0 ~ 31.0 V
>15.5 V
>31.0 V
Power
0 – 100%
100 - 115%
> 115%
Meaning
What to do?
Power OK
Normal operation
Over Load
Reduce the load and/or check the
Protection
AC wiring for possible short
circuits. Then reset the inverter
manually by switching the main
switch off and on again.