EN
TROUBLE SHOOTING GUIDE
Problem
Cause
Pump does not
No mains supply
start
Float stuck
Switch-on height
(automatic ope-
ration)
Not the right
operating mode
(manual mode)
Pump is active
Turbine clogged
but no water is
being delivered
Pump will not
Not the right
switch off
operating mode
Float stuck
Switch-off height
(automatic ope-
ration)
8
Pump will not
start or stops
Remedy
during use.
Check mains supply
Pump switched
off after short
Disconnect pump
operating
periods
from the power sup-
ply and clean float,
float cover and filter
(see 'MAINTENANCE')
The water is below
the switch on height
of 23cm
Slide the operating
mode switch (2) to
"MANUAL"
Disconnect pump
from the power
supply and clean or
unblock the turbine
(see 'MAINTENANCE')
Slide the operating
mode switch (2) to
"AUTO"
ENVIRONMENT
Disconnect pump
from the power sup-
ply and clean float,
float cover and filter
(see 'MAINTENANCE')
Only for EC countries
Do not dispose of power tools into domestic waste.
The water is above
According to the European Guideline 2012/19/
the switch off height
EU for Waste Electrical and Electronic Equipment
of 6.5cm
and its implementation into national right, power
tools that are no longer usable must be collected
separately and disposed of in an environmentally
friendly way.
WARRANTY
VONROC products are developed to the highest
quality standards and are guaranteed free of
defects in both materials and workmanship for the
period lawfully stipulated starting from the date of
original purchase. Should the product develop any
failure during this period due to defective material
and/or workmanship then contact VONROC directly.
Thermal overload
Disconnect from the
safety switch has
power supply, leave
activated
for 2 minutes and
clear the turbine (see
'MAINTENANCE')
Power has
Check fuses and elec-
tripped
trical connections
Turbine clogged
Disconnect pump
from the power
supply and clean or
unblock the turbine
(see 'MAINTENANCE')
Float stuck
Disconnect pump
from the power sup-
ply and clean float,
float cover and filter
(see 'MAINTENANCE')
Water too hot
Ensure that the water
temperature has not
exceeded the maxi-
mum of 35° C
Faulty and/or discarded electrical or
electronic apparatus have to be collected at
the appropriate recycling locations.
WWW.VONROC.COM