Basic Functions
In the 'Off' state
Press and hold the button for 2 seconds to turn it on.
Single Measurement
Short press the button to start a single measurement.
Continuous Measurement
Press and hold the button for 2 seconds to start continuous
measurement.
Multi-function Measurement
Just press the button, you can switch distance,
area, volume, and V Pythagorean measurements.
Benchmark Setting
Short press the button to enter the front and rear reference
setting mode.
1. Set the machine front end
as the starting reference.
2. Set the machine back end as
the starting reference.
Notice:
In the future reference measurement, the measured data
displayed includes 8cm of the body size.
Shutdown
Press and hold for 2 seconds tot turn off.
Clear Data
Short press the buton to clear the date.
Correction Function Setting
Step 1
When the product is in the off state, if press and hold
the 'ON' button for 5 seconds, the calibration mode
can be performed and the screen displays (boot) at
this moment.
Step 2
Precision adjustment setting: In calibration mode,
again press and hold the 'ON' button for 2 seconds
to enter the precision adjustment setting. The
screen will display the present precision setting
(such as CAL.0). The precision for the machine can
be adjusted from -7 to +7mm, and you just short-press the button
to get it.
Step 3
Press and hold the 'ON' button for 1 seconds to switch to another
unit of measure.

ENGLISH