Clip connection
Illustration
The suction hose is equipped with a clip
system. All C-35/C-DN-35 accessories can
be connected.
Operation
Turning on the Appliance
Plug in the main plug.
Switch on the appliance at the main
switch.
Cleaning areas that are difficult to
Illustration
Press the chassis latches and remove
the vacuum unit.
Illustration
Clean areas that are difficult to access
or steps.
Turn off the appliance
Switch off the appliance at the main
switch.
Pull out the mains plug.
After each operation
Empty the container.
Vacuum and wipe the appliance inside
and outside with a damp cloth.
Storing the Appliance
Illustration
Store the suction hose, the manifold
and the mains cable as shown in the il-
lustration.
Place the appliance in a dry room and
secure it from unauthorized use.
16
access
Caution
Risk of injury and damage! Observe the
weight of the appliance when you transport it.
Hold the appliance at the handle and at
the suction pipe to transport it.
When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.
This appliance must only be stored in inte-
rior rooms.
Maintenance and care
Danger
First pull out the plug from the mains before
carrying out any tasks on the machine.
Dust extracting machines are safeguards
for the prevention or elimination of hazards
defined in the regulations of BGV A1.
In order to carry out maintenance work,
–
the user must disassemble, clean and
service the unit, in so far as this is pos-
sible without endangering maintenance
personnel and other persons. Suitable
precautions include decontamination
before the unit is disassembled. Pre-
cautions must be taken for local filtered
forced air ventilation at the place where
the unit is dissassembled, the cleaning
of the maintenance surface and suita-
ble protection of the personnel.
The outside of the unit should be
–
cleaned thoroughly and any harmful
substances removed. Alternatively, a
sealed coating may be applied before
the unit is removed from the danger ar-
ea. All unit parts are to be considered
contaminated when they are removed
from the danger area.
– 4
EN
Transport
Storage