CHARGING AND USE
•The IDX-200 is shipped factory set at the specified intensity for optimal
performance during inspections.
•Turn
flashlight
housing and place included Ni-MH batteries positive end towards head of flashlight.
•Replace tail cap by screwing into flashlight housing.
•The IDX-200 has one switch (on and off) on rear of tail cap. Prior to using the unit,
ensure that the switch is in the off position (no light illuminating from the
flashlight). Press the switch once to turn the flashlight on. Instant-on
operation ensures that the UV-A LED will reach full intensity immediately. Check to
see if the unit is operating optimally.
• Press switch again to turn the flashlight off.
UV INTENSITY VERIFICATION
To ensure that your IDX-200 flashlight is operating at the required
UV intensity, it should be checked periodically. The AccuMAX ™ XRP-3000
radiometer/photometer kit uses a UV-A sensor detector to accurately measure
ultraviolet irradiance. For more information about these units, please contact the
Customer Service Department at Spectro-UV. Call toll-free 1-866-230-7305.
CARE AND MAINTENANCE OF FLASHLIGHT
•It is suggested to regularly replace or lubricate the included O-ring and screw thread
to ensure seal and smooth tail cap removal and replacement.
•Turn off flashlight and ensure unit is cool before cleaning filter glass. Please use lens
tissue, or non-dust cloth for cleaning.
•For long term storage remove battery from flashlight.
•Be sure to use genuine Nano 365 Series replacement parts. Using another
manufacturer's parts could affect product performance and will void the lamp's
warranty.
CARE AND USE OF ALKALINE BATTERIES
•When not in use remove the batteries from the flashlight and store separately.
•Store in a fairly cool environment away from sunlight, heat and humidity. Store
the battery at temperatures between 5 °C and 20 °C (41 °F and 68 °F).
•The battery self-discharges during storage. Higher temperatures (above 20 °C or 68
°F) will reduce the battery life.
•Alkaline batteries are subject to disposal and recycling regulations that vary by
country and region. Always check and follow your applicable regulations before
disposing of any battery.
WARRANTY
The warranty policy for the IDX-200 is provided on the Certificate of Limited
Warranty enclosed separately with each unit. The part number is located in
the center of the flashlight and serial number is located below the lamp head.