Descargar Imprimir esta página

Quick WCD 1022 Manual De Instalacion Y Uso página 14

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

OPERATION / SYSTEM ERRORS AND PROBLEMS
EN
REMOTE CONTROL DISABLING
The control panel is disabled in the following cases:
• When the enablement button is pressed.
• When there are several controls in parallel and another is activated.
Passage to the disabled state is signalled from the control with a prolonged sound of around one second and the follow-
ing slow flashing of the enablement Leds. The direction buttons are disabled.
MULTIPLE CONTROLS IN PARALLEL
Several WCD control instruments can be installed in parallel. In this case, only one control panel can function at a time.
The active control panel is always the last one to be activated; the other in parallel are automatically disabled. If a com-
mand is sent to the windlass by the last control panel enabled, the boat movement direction will be indicated by the rela-
tive Led which will light up also on the other disabled controls.
Disablement/enablement of the sound of the control
The acoustic signals emitted by the control can be disabled.
Carry out the following procedure:
• Remove power to the control.
• Keep the enablement key pressed and supply power to the control which will emit a short sound.
• Release the enablement key and wait for the control to perform the testing of the Led and for it to be disabled (slow
flashing of the enablement Led).
The acoustic signals emitted by the control can be re-enabled.
Carry out the following procedure:
• Remove power to the remote control.
• Keep the enablement key pressed and supply power to the control which will emit two short sounds.
• Release the enablement key and wait for the control to perform the testing of the Led and for it to be disabled (slow
flashing of the enablement Led).
SYSTEM ERRORS
When the control panel is switched on, it may signal the presence of system errors.
Checksum error flash
If the error is detected, all the LEDs will flash quickly.
In this case an assistance point or the Quick
SYSTEM PROBLEMS
System problems are listed below, divided into two categories:
automatic reset problems and manual reset problems.
AUTOMATIC RESET PROBLEMS
Resetting after problems of this type occurs automatically, as soon as the cause that has generated the problem disap-
pears.
Insufficient voltage supply
The signalling occurs only when the control is enabled.
The problem is signalled if the power supply voltage descends below 10.5Vdc for more than one second. Resetting after
this problem occurs if the power supply voltage exceeds the threshold of 11.5Vdc for more than one second.
Check the charge state of the battery group that supplies power or the electrical circuit.
In the presence of this problem the enablement Leds slowly flash with a sound, when they are switched off.
Pressing opposite buttons
If both direction buttons are pressed by mistake, the direction Leds flash and the command to the windlass is interrupted.
As soon as the direction buttons are released the Leds go off and the control panel is ready for new operations.
14
customer service must be contacted as soon as possible.
®
WCD 1022 REV001A

Publicidad

loading