10. Troubleshooting guide

Fault
The motor does not
start
The equipment
does not spray, or
only sprays at re-
duced power, even
though the tank
is full
Too much spray
mist
Motor stops sud-
denly
Anl_GE_WS_18-35_Li_SPK13.indb 25
Anl_GE_WS_18-35_Li_SPK13.indb 25
GB
Possible cause
a) Equipment not switched on
b) Connections on motor loose
c) Battery not correctly inserted
a) Nozzle completely or partly clogged
b) The fi lter element in the handle is com-
pletely or partly soiled
c) Liquid too viscous and therefore unsui-
table
a) Distance from object is too great
b) Spray width too great
Battery spent
- 25 -
Remedy
a) Turn On/Off switch to "I" (see
6.)
b) Have the equipment checked
by a customer service work-
shop
c) Remove battery and reinsert
(see 5.)
a) Clean the nozzle (see 7.2)
b) Clean the fi lter element (see
section 7.4)
c) Remove liquid, clean equip-
ment and container (see 7.)
a) Reduce spraying distance
b) Reduce spray width (see
6.3.2)
Insert a charged battery (see
5.3)