Descargar Imprimir esta página

Gude OR 1500-7 Traducción Del Manual Original página 30

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 61
ENGLISH
Operation OR 2000-9 DT &
OR 2500-11 DT
Setting the heating power
1) Plug the power cord into an appropriate outlet.
Make sure your power supply is properly
protected.
2) Switch on the device with the mains switch [1]
(beep sounds and switch lights up red).
3) Use the power level button [2] to set the desired
heating power.
Press button 1x = high power
(OR 2000-9 DT: 2000 W / OR 2500-11 DT: 2500 W)
Press button 2x = medium power
(OR 2000-9 DT: 1200 W / OR 2500-11 DT: 1500 W)
Press button 3x = low power
(OR 2000-9 DT: 800 W / OR 2500-11 DT: 1000 W)
Press button 4x = device is on standby
Note:
The power levels are indicated by small symbols
at the top right of the display [3].
Temperature setting
1) Use the power switch [1] to switch on the
device.
2) Press the power level button [2].
The number "88" flashes on the display [3].
3) Press the mode button [4].
The display [3] shows "24 °C" (or 75 °F) and a
flashing thermometer symbol.
4) Use the °C / °F button [5] to select the desired
unit for the temperature display.
5) Use the + [6] and - [7] buttons to set the desired
temperature. The temperature value is shown
on the display [3] and can be changed at any
time.
Note:
When the desired temperature is reached, the
thermometer symbol lights up continuously. If the
temperature drops and the device has to heat up,
the thermometer symbol flashes again.
26
Programming the switch-off time (AUTO OFF).
This function is used to set when the oil-filled radiator
switches off automatically.
1) Once the temperature is set, press the mode
button [4] again. "AUTO OFF" flashes on the
display [3].
2) Use the + [6] and - [7] buttons to set a time
between 1 and 24 hours.
3) The "AUTO OFF" indicator lights up continuously
after approx. 10 seconds. The oil-filled radiator
will then switch off at the set time.
Programming the switch-on time (AUTO ON).
This function is used to set when the oil-filled radiator
switches on automatically.
1) Once the temperature is set, press the mode
button [4] twice. "AUTO ON" flashes on the
display [3].
2) Use the + [6] and - [7] buttons to set a time
between 1 and 24 hours.
3) The "AUTO ON" indicator lights up continuously
after approx. 10 seconds. The oil-filled radiator
will then start heating at the set time.
Switching off the device
1) Keep pressing the power level button [1] until
the display [3] turns off.
2) Use the mains switch [3] (position 0) to switch
off the device.
3) Pull out the power cord from the wall outlet.