Nivotemp 61-0-WW
1 Introduction
This quick guide will assist you in starting up the unit. Follow
the safety notices or injury to health or property damage may
occur. Carefully read the original operating instructions in-
cluding information on maintenance and troubleshooting
prior to startup. These are located on the included CD and on-
line at
www.buehler-technologies.com
Please direct any questions to:
Bühler Technologies GmbH
Harkortstraße 29
40880 Ratingen
Germany
Tel.: +49 (0) 21 02 / 49 89-0
Fax: +49 (0) 21 02 / 49 89-20
These operating instructions are a part of the equipment. The
manufacturer reserves the right to change performance-, spe-
cification- or technical data without prior notice. Please keep
these instructions for future reference.
1.1 Intended Use
The level switches in the Nivotemp 61-0-WW series are used to
monitor fill levels in tanks. These level switches are designed
to be installed on tank tops. The liquid level can be read on the
scale. Up to four switching contacts or a Reed-contact also en-
able electronic liquid level monitoring.
Different versions also allow for use in aggressive mediums.
Please note the technical data in the appendix for the specific
intended use, existing material combinations, as well as tem-
perature limits.
WARNING
All device models are solely intended for industrial applica-
tions. They are not safety components. The devices must not
be used if failure or malfunction thereof jeopardises the
safety and health of persons.
Use in explosive areas is prohibited.
1.2 Scope of Delivery
• Level switch
• Product documentation
• Connection/mounting accessories (optional)
2 Safety instructions
The equipment must be installed by a professional familiar
with the safety requirements and risks.
Be sure to observe the safety regulations and generally applic-
able rules of technology relevant for the installation site. Pre-
vent malfunctions and avoid personal injuries and property
damage.
BX100007 ◦ 05/2022
The operator of the system must ensure:
• Safety notices and operating instructions are available
and observed,
• The respective national accident prevention regulations
are observed,
• The permissible data and operational conditions are
maintained,
• Safety guards are used and mandatory maintenance is
performed,
• Legal regulations are observed during disposal,
• compliance with national installation regulations.
DANGER
Toxic, acidic gases/liquids
Protect yourself from toxic, corrosive gasses/liquids when
performing any type of work. Wear appropriate protective
equipment.
3 Transport and storage
Only transport the product inside the original packaging or a
suitable alternative.
The equipment must be protected from moisture and heat
when not in use. It must be stored in a covered, dry, dust-free
room at room temperature.
4 Setup and connection
DANGER
Electric voltage
Risk of electric shock
a) De-energise the system.
b) The equipment may only be installed, maintained and
put into operation by instructed, competent personnel.
c) Always observe the applicable safety regulations for the
operating site.
DANGER
Toxic, acidic gases/liquids
Protect yourself from toxic, corrosive gasses/liquids when
performing any type of work. Wear appropriate protective
equipment.
4.1 Installation
Please note before installing the level switch!
After transport and delivery of the level switch, the switching
status of the bistable contacts may be different than required
for proper operation.
Therefore slide the float for the level switch along the level
switch tube from below immediately before installation.
This ensures all built-in bistable contacts have a clearly
defined switching status (NC or NO).
The level switches come fully assembled and can be mounted
to the tank using the included screws and seals. Please be sure
the floats can move freely and to have enough space between
the tank wall and add-ons.