Descargar Imprimir esta página

Accessories; Installation Information; Battery Preparation; Battery Installation And Preparation - Lavor COMFORT XXS Serie Manual

Publicidad

• DIP-SWITCH CONFIGURATION FOR BATTERY
CHARGER CBHD2 24V 20A
To set the charging curve type for Pb-Acid or GEL/AGM
batteries it is necessary to operate on the dip-switches
placed inside the battery charger ( Photo I -4 ).
The dip-switches for the setting of the charging curve
are on the control card ( Photo I - 4 ) that is placed
behind the lower panel of the battery charger ( Photo
I - 1 ). It is also possible to reach the dip-switches by
removing the plastic cap ( Photo I - 5 ). For the setting
of the charging curve it is necessary to operate on the
dip-switches of the group indicated as SW1 ( Photo
I - 6 ), placing them as shown in the table ( Photo
I - 6) at page 7.
NOTE: The dip-switches of the group indicated as
SW2
must always be set in the OFF position.
If the machine is supplied with a battery and a
charger, the setting of the machine and the charger
is carried out by the manufacturer.
In the event of changes to the equipment, i.e. the type
of battery and charger, we always recommend that
you contact your authorised service centre both for
the machine setting and the setting of the charger's
charging curve.
As a general rule, the following criteria apply:
For Pb-acid and GEL batteries: charging current of
approx. 10-12% of the capacity in Ah-C20
For lithium batteries: charging current of approx.
40% of the capacity in Ah
Failure to comply may result in serious damage to
the battery and warranty invalidation.
4.4.

ACCESSORIES

Your machine supplier can provide a complete and
updated list of all available accessories, such as
brushes, pad drivers, disks, etc.
5.

INSTALLATION INFORMATION

5.1.

BATTERY PREPARATION

• The technical features of the batteries used must
match those indicated in the technical features sec-
tion. Using different batteries may cause serious
damage to the machine or may require them to be
charged more frequently.
• During installation or when performing any type of
battery maintenance, the operator must be equipped
with adequate safety accessories to prevent accidents.
Work far from open flames, do not short-circuit the bat-
tery poles, do not generate sparks and do not smoke.
The batteries are normally supplied full of acid solu-
tion (for the Pb-Acid type) and ready for use. In any
case, follow the steps indicated in the manual sup-
plied with the battery and carefully follow the instruc-
tions regarding safety and operating procedures.
5.2.
BATTERY INSTALLATION AND
PREPARATION
• These operations must be carried out by special-
ised personnel.
Make sure the two tanks are empty. If not, empty
them in accordance with the specific procedure.
Lift the recovery tank by 90°, making sure it is stable
in that position. This provides access to the battery
compartment from the top.
Disconnect the Anderson connector of the battery
wiring from the Anderson connector of the machine
wiring. Always hold the connectors with the hands
and never pull on the cables.
• Attach the battery wiring to the battery, con-
necting the terminals only on the poles marked
with the same symbol (red wiring "+", black wiring
"-")! A battery short-circuit may cause an explosion!
Run the cables toward the wiring outlet opening
(on one side of the box, only for Pb-Acid batteries),
tighten the terminals at the poles and cover them
with Vaseline. Insert the battery putting the opening
in the box (only for the Pb-Acid battery) in a position
to run the electric wiring to the connector of the ma-
chine wiring. After checking that all the controls on
the panel are in position "0" or at rest, connect the bat-
tery connector to the machine connector.
• Close the battery compartment (lowering the re-
covery tank) making sure not to crush any wires.

5.2.1. SETTINGS THROUGH THE CONTROL PANEL

Make sure that the Key is turned to OFF position (O),
Make sure that the Key is turned to OFF position (O),
then press simultaneously the buttons
then press simultaneously the buttons
(Picture N-1) and
control panel (Picture N).
At the same time, turn the key to ON position (I)
When, on the display, it appears the word "PASS-
WORD" (picture N-7), release the buttons previously
(picture N-7), release the buttons previously
pressed. Now, by using the buttons
(Picture N-1), it is possible to scroll through the settable
parameters which you can choose from dashboard:
- TIPO BATTERIA
- LINGUA
To select and change the desired parameter, press the
To select and change the desired parameter, press the
button
(-) "SPEED REDUCTION"
(-) "SPEED REDUCTION" (Picture N-6) or
press the button
To exit from the calibration select the button
"SUCTION" (Picture N-2)
MEANING OF SETTABLE PARAMETERS:
BATTERY TYPE
Range: Pb Acid / Gel
32
"BRUSHES"
(-) "SPEED" (Picture N-6) on the
"BRUSHES"
(BATTERY TYPE)
(LANGUAGE)
"FORWARD / REVERSE GEAR".
"FORWARD / REVERSE GEAR".

Publicidad

loading