5. ChARgINg PROgRAMS
Choose program by pressing the moDE-button.
Adjust parameters according to "CHARGiNG" (6–8).
Press START/PAuSE button to start the selected program.
The table explains the different Charging Programs:
Program
battery Size
(Ah)
40-1500 Ah
NORMAL
20-750 Ah
40-1500 Ah
Ca/Ca
20-750 Ah
40-1500 Ah
AgM/gEL
20-750 Ah
40-1500 Ah
AgM POWER
20-750 Ah
40-1500 Ah
SUPPLY
20-750 Ah
Current
battery size Min
20 A
40 Ah
30 A
60 Ah
40 A
80 Ah
50 A
100 Ah
70 A*
100 Ah
• Using higher current than recommended may result in batteries not being completely charged.
•
Using lower current than recommended will prolong the charging time.
• T he currents are the maximum recommended current for battery charging. If a parallel consumer is connected
then the current setting could be increased with this current value.
• S ome battery manufacturer could recommend different values. Please check with the manufacturer if uncertain.
The main recommendations are that Gel batteries should be charged in the lower current range, Power AGm's in
the upper range and most other battery types in the mid-range.
*)
70/35A Could only be selected for Supply program
Risk for short circuiting the battery cables. Connect charger cables to the charger before
connecting the battery
Risk for electrical shock if touching positive and negative terminals when charging
use for WET and mF batteries.
use for Ca/Ca batteries. use Ca/Ca-program to maximize charge
with minimum loss of fluid. including RECoND step. Recond
your battery once per year and after deep discharge to maximise
lifetime and capacity.
For AGm and GEL batteries which are recommended to receive
lower voltage charge.
use for AGm batteries which are recommended to receive higher
voltage charge.
use as 12V/24V power supply or use for float maintenance
charging when 100% capacity of the battery is required. Supply
program activates step 7 without time or voltage limitation.
Supply program enables the charger to deliver 70A/12V or
35A/24V for 30 seconds.
12V
battery size Max
100 Ah
150 Ah
200 Ah
-
-
Explanation
Current
battery size Min
10 A
20 Ah
15 A
30 Ah
20 A
40 Ah
25 A
50 Ah
35 A *
50 Ah
Temp range
- 20 °C–+ 50 °C
(-4ºF–+122ºF)
- 20 °C–+ 50 °C
(-4ºF–+122ºF)
- 20 °C–+ 50 °C
(-4ºF–+122ºF)
- 20 °C–+ 50 °C
(-4ºF–+122ºF)
- 20 °C–+ 50 °C
(-4ºF–+122ºF)
24V
battery size Max
50 Ah
75 Ah
100 Ah
-
-
26