Regulatory symbols
With this symbol, Bellman & Symfon confirms that the product meets the Medical Device
Regulation EU 2017/745.
This symbol indicates the manufacturer's serial number so that a specific medical device can be identi-
fied. It's available on the product and gift box.
This symbol indicates the manufacturer's catalogue number so that the medical device can be
identified. It's available on the product and gift box.
This symbol indicates the medical device manufacturer, as defined in EU Directives 90/385/EEC,
93/42/EEC and 98/79/EC.
This symbol indicates that the user should consult the instructions for use.
This symbol indicates that it is important for the user to pay attention to the relevant warning notices
in the user guides.
This symbol indicates important information for handling and product safety.
Temperature during transport and storage: –10° to 50° C, 14° to 122° F
Temperature during operation: 0° to 35° C, 32° to 95° F
Humidity during transportation and storage: <90%, non-condensing
Humidity during operation: 15% to 90%, non-condensing
Atmospheric pressure during operation, transportation and storage: 700hpa to 1060hpa
This device is designed such that it functions without problems or restrictions if used as intended,
Operating
conditions
unless otherwise noted in the instructions for use.
With this CE symbol, Bellman & Symfon confirms that the product meets EU standards for health,
safety, and environmental protection as well as the Radio Equipment Directive 2014/53/EU.
This symbol indicates that the product shall not be treated as household waste. Please hand over your
old or unused product to the applicable collection point for the recycling of electrical and electronic
equipment or bring your old product to your hearing care professional for appropriate disposal.

Technical specifications

Dimensions
165  130  36 mm, 6.5  5.1  1.4"
Weight
590 g, 20.8 oz. including batteries
Battery power
4 x 1.5V LR14 (C) alkaline batteries
Mains power
7.5 V DC / 1500 mA with optional power adapter
10
Power consumption
Active: 1000 mA, idle position: 0.1 mA
Operating time
2 – 3 years with alkaline batteries
Sound signal
Adjustable up to 93 dBA @ 1 m, frequency range: 500 – 1000 Hz
Produces individual sound signatures
Light signal
4 colored LEDs that react to the incoming Visit signals
5 white LEDs that alert with a clear light signal
Bed shaker outlet
Vibration power: 2.0 – 4.0 VDC (max. 500 mA)
Radio frequency
868.30 MHz.
Coverage
50 – 250 m, 55 – 273 yards depending on the characteristics
of the building. Coverage is reduced if walls and large objects
block the signal.
In the box
BE1450 Visit portable receiver
4  1.5V LR14 batteries
Wall bracket
Screws and plugs
Troubleshooting
If
Try this
The receiver seems to be
The batteries are depleted. Replace them with
turned off
4  1.5V LR14 alkaline batteries.
The power LED is yellow when
The battery level is low. Replace them with 4  1.5V
the receiver is activated
LR14 alkaline batteries.
The receiver does not
Check the transmitter batteries and connections.
respond when a transmitter
Move the receiver closer to the transmitter to make
is activated, but works when I
sure it's within radio range.
use the test button
Check that the receiver is set to the same radio key
as the other units in the Visit system, see
the radio
The receiver is activated for no
There is probably another Visit system installed
apparent reason
nearby that triggers your system. Change the radio
key on all units, see
The receiver is too quiet
Turn up the volume using the red volume dial on the
top of the unit.
The receiver is not flashing
Check that the flash signal switch on the back of the
unit is set to the ON position.