Descargar Imprimir esta página

Thermostat; Light - Tefcold MD702 Guia Del Usuario

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 39

THERMOSTAT

The thermostat is placed in the control panel.
The thermostat has been pre-set and in most cases it is not necessary to adjust the settings.
When turning on the cabinet the display will show the current temperature in the cabinet.
Display set temperature:
Press this key and the display will show the set temperature. Press the key again to
return to normal reading
Set new temperature:
Press this key continuously for more than 3 seconds and the display shows the set
temperature.
Press this key to increase the set temperature.
Press this key to lower the set temperature.
Press this key to save the new settings. The display will flash with the new value and
will then return to normal reading.
Alarm codes:
'E1'
Flashing in the display: indicates that the cabinet sensor is defective.
The cabinet will strive to keep the set temperature until it has been repaired.
Unlock keyboard:
Press both these keys for 5 seconds to activate the keyboard.
+
On/Off:
Press this key to turn on/off the cabinet.

LIGHT

Press this key to turn the light on/off. (Keyboard must be unlocked)
5

Publicidad

loading

Este manual también es adecuado para:

Md1002Md1402Md1902