INSTALACIÓN DE LA UNIDAD INTERIOR
4 INSTALACIÓN DE LA UNIDAD INTERIOR
4.1 DESEMBALAJE
Al abrir el embalaje, la unidad RPIH está del revés. Se debe girar entre dos técnicos.
Checking Scale
Checking Scale
Checking Scale
Checking Scale
4.2 COMPONENTES SUMINISTRADOS DE FÁBRICA
(Cut and Take Out it
(Cut and Take Out it
(Cut and Take Out it
(Cut and Take Out it
from the Carton Board)
from the Carton Board)
from the Carton Board)
from the Carton Board)
Compruebe que los siguientes accesorios están incluidos con la unidad interior.
Cross Recessed
Cross Recessed
Cross Recessed
Cross Recessed
Head Screws (M5)
Head Screws (M5)
Head Screws (M5)
Head Screws (M5)
Washer with Insulation
Washer with Insulation
Washer with Insulation
Washer with Insulation
Arandela con aislante (M10)
Material (M10)
Material (M10)
Material (M10)
Material (M10)
Washer (M10)
Washer (M10)
Washer (M10)
Washer (M10)
Arandela (M10)
Tubo de desagüe
Drain Hose
Drain Hose
Drain Hose
Drain Hose
Abrazadera
Hose Clamp
Hose Clamp
Hose Clamp
Hose Clamp
Aislamiento (5Tx100x200)
Pipe Insulation
Pipe Insulation
Pipe Insulation
Pipe Insulation
Aislamiento de tuberías (Ø28x125)
Pipe Insulation
Pipe Insulation
Pipe Insulation
Pipe Insulation
Aislamiento de tuberías (Ø43x125)
Cord Clamp
Cord Clamp
Bridas de plásticos
Cord Clamp
Cord Clamp
?
Cord Clamp
Cord Clamp
Cord Clamp
N O TA
Cord Clamp
•
Si falta cualquiera de los accesorios, póngase en contacto con su proveedor.
Insulation
Insulation
Insulation
Insulation
•
El panel de aire, el mando a distancia y las tuberías de bifurcación son accesorios opcionales y no están incluidos.
(5Tx50x200)
(5Tx50x200)
(5Tx50x200)
(5Tx50x200)
4.3 ESPACIO DE INSTALACIÓN (UBICACIÓN, PRECAUCIONES, CONDICIONES Y ORDEN)
Insulation
Insulation
Insulation
Insulation
(5Tx100x200)
(5Tx100x200)
(5Tx100x200)
(5Tx100x200)
!
Insulation
P E L I G R O
Insulation
Insulation
Insulation
(5Tx25x500)
(5Tx25x500)
(5Tx25x500)
(5Tx25x500)
•
No instale las unidades interiores en el exterior. Existe riesgo y
fugas eléctricas.
•
Tenga en cuenta la distribución de aire desde cada unidad
interior y seleccione una ubicación adecuada para obtener una
temperatura uniforme en toda la estancia.
•
Evite los obstáculos que dificulten la entrada o la descarga de aire.
•
Tenga en cuenta los siguientes puntos cuando instale las unidades
interiores en un hospital u otros lugares en los que existan ondas
electrónicas procedentes, por ejemplo, de equipos médicos.
- No instale las unidades interiores donde las ondas
electromagnéticas se irradien directamente a la caja eléctrica,
el mando a distancia o a su cable.
- Instale las unidades interiores y los componentes lo más
alejados posible o 3 metros como mínimo de la fuente de
radiación electromagnética.
- Disponga una caja de acero e instale en su interior el mando
a distancia. Tienda el cable del mando a distancia por un
conducto de acero dispuesto para ello. Conecte el cable de
tierra a la caja y al conducto.
- Instale un filtro de ruido si la fuente de alimentación emite
ruidos molestos.
- No instale la unidad interior, la unidad exterior, el mando a
18
PMML0529 rev.1 - 02/2021
Accessory
Accessory
Accessory
Accessory
Accessory
Checking Scale
(Cut and Take Out it
from the Carton Board)
Cross Recessed
Head Screws (M5)
Washer with Insulation
Material (M10)
Accesorio
Washer (M10)
Drain Hose
Hose Clamp
Pipe Insulation
Pipe Insulation
Cord Clamp
Cord Clamp
Insulation
(5Tx50x200)
Insulation
(5Tx100x200)
Insulation
(5Tx25x500)
Purpose
Q'ty
Purpose
Q'ty
Q'ty
Purpose
Q'ty
Purpose
For Adjusting Space of False
For Adjusting Space of False
Q'ty
Purpose
For Adjusting Space of False
For Adjusting Space of False
For Adjusting Space of False
Ceiling Opening and
Ceiling Opening and
Ceiling Opening and
1
1
Ceiling Opening and
Ceiling Opening and
1
1
1
Position of the Unit
Position of the Unit
Position of the Unit
Position of the Unit
Position of the Unit
4
For Fitting Paper Pattern
4
For Fitting Paper Pattern
4
For Fitting Paper Pattern
4
For Fitting Paper Pattern
4
For Fitting Paper Pattern
4
Cant.
For Unit Installation
4
4
4
4
4
4
1
For Unit Installation
For Drain Hose Connection
For Unit Installation
For Unit Installation
For Unit Installation
Para la instalación de la unidad
1
4
4
4
4
4
1
For Refrigerant Piping
Connection
1
1
1
1
1
1
2
For Drain Hose Connection
For Fixing Remote Control
For Drain Hose Connection
For Drain Hose Connection
For Drain Hose Connection
Para la conexión del tubo de desagüe
Switch Wiring, Louver Sensor
and Insulation of Piping
6
1
1
1
1
1
For Covering Wiring
1
Connection
Para cubrir la conexión de desagüe
1
For Covering Drain
1
1
1
Connection
1
1
For Refrigerant Piping
For Refrigerant Piping
For Covering Drain
For Refrigerant Piping
For Refrigerant Piping
1
1
Connection
Connection
Connection
Connection
Connection
1
1
1
1
1
Para cubrir la tubería de gas/líquido
2
2
4
2
2
For Fixing Remote Control
For Fixing Remote Control
For Fixing Remote Control
For Fixing Remote Control
Switch Wiring, Louver Sensor
Switch Wiring, Louver Sensor
Switch Wiring, Louver Sensor
Switch Wiring, Louver Sensor
and Insulation of Piping
and Insulation of Piping
and Insulation of Piping
and Insulation of Piping
6
6
6
6
For Covering Wiring
For Covering Wiring
For Covering Wiring
For Covering Wiring
1
1
1
1
Connection
Connection
Connection
Connection
For Covering Drain
For Covering Drain
For Covering Drain
For Covering Drain
1
1
1
1
Connection
Connection
Connection
Connection
distancia y el cable a menos de 3 metros de grandes fuentes
For Covering Drain
For Covering Drain
For Covering Drain
For Covering Drain
1
1
de radiación electromagnética (por ejemplo, las generadas
1
1
Connection
Connection
Connection
Connection
por equipos médicos).
•
Este tipo de unidad interior no tiene calentador eléctrico. Está
prohibido instalar un calentador eléctrico en el lugar de instalación.
•
No coloque materiales extraños en la unidad interior y asegúrese
de que no contiene ninguno en su interior antes de instalarla y
de realizar la prueba de funcionamiento. De lo contrario, pueden
producirse fallos, incendios, etc.
•
No instale las tuberías de refrigerante y de desagüe ni la bomba de
desagüe ni realice las conexiones eléctricas sin antes consultar
el manual de instalación. Si no sigue las instrucciones, pueden
producirse fugas de agua, descargas eléctricas, incendios o
lesiones.
•
Monte los pernos de suspensión M10 (W3/8), como se indica a
continuación:
Para losa de hormigón
150~160 mm
Viga en I
Acero
Pernos de suspensión
(W3/8 o M10)
Finalidad
Barra de madera
(rectangular, de 60 x 90mm)
Tuercas
Hormigón
Viga de madera
Perno de eslinga
Perno de
(W3/8 o M10)
anclaje
Arandelas
cuadradas