HARDWARE INSTALLATION:

FCM630A can be installed on the desktop or on the wall, and can be installed in
a cabinet on a pallet. Please refer to the following steps for correct installation.

Wall Installation:

1. Before formally installing the expansion screws, clarify the specific location of
the expansion screws and make a mark.
2. Pay attention to the following points when drilling: First, the drill bit model (ap-
erture) used for drilling refers to the maximum diameter of the expansion tube
equipped with the expansion screw; second, the drilling depth refers to the
length of the expansion tube, slightly deeper than 5~10mm .
3. After the expansion tube is inserted into the punched hole, it can be tapped
lightly with a hammer to make the expansion tube and the wall flat.
4. Fix the equipment well and fix the self-tapping screw in the expansion tube.
Self-tapping Screw Specifications:
Punch: JMB-40B
Use line: 1018
Rolling diameter: Φ3.25MM
Dental plate: M4-16T
Expansion Screw Specifications:
2.50±0.2
+0.5
*30.00
-0.5
This size measures the
side with no opening
~3~
Schematic Diagram of Wall-mounted Installation:

Rack Installation:

Just fix the device on a standard rack.
~4~