UK
Troubleshooting
Fault
The appliance is
not working
Appliance is noisy
or works
intermittently
Compressor runs
but no ice is made
Ice cubes not fully
formed
Not producing
enough ice
Technical Specifications
Model
Voltage
CB920 230V 50Hz
CB922 230V 50Hz
CB923 230V 50Hz
3
Probable Cause
The appliance is not switched
on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Ambient temperature below
10°C
Water supply
Bin is full
Power fluctuations
Refrigerant leak or block in the
refrigerant system
Bin is full
Blocked nozzle
First ice making cycle
Ice melted
Ambient temperature too high
Water pressure too low
Power Current
Storage
205W
0.9A
380W
1.65A
680W
2.95A
Check the appliance is plugged in correctly and
switched on
Call POLAR agent or qualified technician
Replace the plug fuse
Check power supply
Call POLAR agent or qualified technician
Move appliance to a warmer position
Check water supply is on and supply hoses are
not blocked
Empty bin
Turn off the ice maker and restart after 3 minutes
Call POLAR agent or qualified technician
Empty bin
Clean nozzle jets
Use ice from second cycle
Do not leave ice in bin for extended periods
Reloacte appliance to a suitable position
Check water inlet hose/inlet hose filter for
blockages
Bin
Ice
Making
Refrigerant
(kg)
Capacity
9
25kg/hour
14
40kg/hour
20
60kg/hour
Action
Dimensions
h x w x d mm
R134a
800 x 400 x 495
200g
R134a
880 x 490 x 535
300g
R134a
930 x 560 x 570
420g
Weight
(kg)
41
53
67