OPERATION METHOD

Shift the machine outdoors, use wire
of no less than 2.5 mm
2
terminal connected to the ground. One end of the wire is
pressed below the nut, screwed up tightly, and the other
end is connected with the metal rod shape article (such
as the iron nail and the apener), and inserted into soil.
• Starting the generator
Filling oil
Remove the oil filler cap, fill oil of proper model. As to
dosage, refer to Page 3. Use the funnel far filling, in case of
careless spilling, clean the ground to avoid slipping.
Oil specification table
SAE
TEMP

AMBIENT TEMPERATURE

Filling fuel
Open the fuel tank cap and fill gasoline, the fuel leveler's
position will display gasoline mass in the fuel tank and take
care the maximum fuel position shall not exceed the inner
strainer of the tank when filling.
Unit grounding
to make the machine and grounding
Upper level
No exceeding
this level
WARNING
Keep away from the fire source and heat
source when filling; do not fill gasoline when be operating.
Connect electric battery (electric start only)
Turn on the fuel valve lever
ON
Close the choke valve
Start the generator
START
Start the generator recoil start
5
Connect the storage battery wire to
the storage battery, red far positive
electrode and green far the negative
electrode, and make sure screwing
the nut tightly. Not contact between
positive electrode to negative
electrode to avoid short circuit.
After connection, metal parts of
two pieces of wire shall keep at
least 15 mm safety distance, and
be protected by rubber cover.
Turn the fuel valve lever to
ON and let the fuel flow into
the carburetor.
When the unit is in cold state,
move the choke valve to the
full closed position, and half
closed position in thermal
state. If the generator unit is
not started for two times in
succession, move the choke
valve to the open position
and then to operate the
switch or hand-pull starter.
Turn the engine switch on the
control panel to ON. Or press
it to Start if it's electrical start
state, then generator unit can
be started. In order to extend
the service life of the storage
battery, do not press on the
switch for more than 3
seconds and the interval
between two pressongs
should be longer than 10
seconds.
Start via the pull wire: Pull
the wire gently to connect
the disc to the starting bowl
inside the unit. Pull the wire
out in an instant action and
the generator unit will be
started, please conduct the
above operation with the
choke valve.