Change lamp

DANGER:
Disconnect mains plug before opening the working lamp!
Let working lamp cool down before touching it (at least 15 minutes).
Any contact might cause burns.
Step
Operation
1
Turn working light on the "back". Press rubber lip down.
Figure 3: Remove rubber lip
2
Unscrew the 4 screws of the protective cover from casing. Remove protective
cover.
Figure 4: Open protective cover
3
Remove lamp from socket by pulling it upwards.
Figure 5: Socket
4
Insert new lamp with light pressure.
5
Put protective cover on the casing. Screw the 4 screws of the protective cover into
the protective cover. Put sealing over protective cover again.
IMPORTANT: See that the sealing sits correctly between casing and
protective cover.
Instruction manual
Pos. Description
7
Protective cover
8
Rubber lip
13
Casing
Table 4: Remove rubber lip
Pos. Description
13
Casing
15
Protective cover screws
Table 5: Open protective cover
Pos.
Description
6
Socket
9
Lamp
Table 6: Socket