Descargar Imprimir esta página

Maintenance - Power Stroke PSi2100 Serie Manual Del Operador

Publicidad

Idiomas disponibles

Idiomas disponibles

NOTE: Most batteries will be completely charged after
30 to 120 minutes. However, it is highly recommended
that you refer to your battery manufacturer's instructions
for specific charge times.
 Unplug battery charging cable assembly and store for
later use.
WARNING:
When servicing, use only identical replacement parts.
Use of any other parts could create a hazard or cause
product damage.
WARNING:
Before inspecting, cleaning, or servicing the machine,
shut off engine, wait for all moving parts to stop, and
disconnect spark plug wire and move it away from
spark plug. Allow 30 minutes of cool down time before
performing any maintenance. Failure to follow these
instructions can result in serious personal injury or
property damage.
NOTICE:
Periodically inspect the entire product for damaged,
missing, or loose parts such as screws, nuts, bolts, caps,
etc. Tighten securely all fasteners and caps and do not
operate this product until all missing or damaged parts
are replaced. Please call 1-877-617-3501 or contact an
authorized service center for assistance.
GENERAL MAINTENANCE
Keep the generator in a clean and dry environment where it
is not exposed to dust, dirt, moisture, or corrosive vapors.
Do not allow the cooling air slots in the generator to become
clogged with foreign material such as leaves, etc.
Do not use a garden hose to clean the generator. Water
entering the fuel system or other internal parts of the unit can
cause problems that will decrease the life of the generator.
To clean the unit:
 Use a soft bristle brush and/or vacuum cleaner to loosen
and remove dirt and debris.
 Clean air vents with low pressure air that does not exceed
25 psi.
 Wipe the exterior surfaces of the generator with a damp cloth.
OPERATION
HIGH ALTITUDE OPERATION
Specific modifications are needed for high-altitude operation.
Please contact your authorized service center for important
information regarding these modifications. Operating this
engine without the proper altitude modification may increase
the engine's emissions and decrease fuel economy and
performance.

MAINTENANCE

CHECKING/CLEANING AIR FILTER
See Figures 13 - 14.
For proper performance and long life, keep air filter clean.
 Loosen the screws on the front cover. Remove front cover
and set aside.
 Loosen the screw in the center of the air filter cover.
Remove air filter cover and set aside.
 Remove the air filter.
 Wash the air filter with warm, soapy water. Rinse and
squeeze to dry.
 Reinstall the air filter.
NOTE: Make sure the filter is seated properly inside the
generator. Installing the filter incorrectly will allow dirt to
enter the engine, causing rapid engine wear.
 Reinstall the air filter cover. Tighten screw to secure.
 Reinstall the front cover. Tighten screws to secure.
CHANGING ENGINE LUBRICANT
See Figure 15.
 Loosen the screw on the side cover. Remove side cover
and set aside.
 Unscrew the oil cap/dipstick and remove.
 Tilt the generator to the side and allow lubricant to drain
from the oil fill hole into an approved container.
NOTE: Drain the lubricant while the engine is still warm
but not hot. Warm lubricant will drain quickly and more
completely.
Do not change engine lubricant while it is hot. Accidental
contact with hot engine lubricant could result in serious
burns.
 Return the generator to an upright position and refill with
lubricant following the instructions in the Checking/
Adding Lubricant section previously in this manual.
For amount of lubricant needed to refill, see Product
Specifications earlier in this manual or the accompanying
engine manual, if applicable.
 Replace and secure the oil cap/dipstick.
 Reinstall the side cover. Replace the screws and tighten
securely.
15 — English
WARNING:

Publicidad

loading