Descargar Imprimir esta página

Spark Arrestor - Power Stroke PS903250 Serie Manual Del Operador

Publicidad

Idiomas disponibles

Idiomas disponibles

CLEANING THE EXHAUST PORT AND MUFFLER
Depending on the type of fuel used, the type and amount of
lubricant used, and/or your operating conditions, the exhaust
port and muffler may become blocked with carbon deposits.
If you notice a power loss with your gas-powered products,
you may need to remove these deposits to restore perfor-
mance. We highly recommend that only qualified service
technicians perform this service.

SPARK ARRESTOR

See Figure 16.
NOTICE:
This product is equipped with a spark arrestor that has
been evaluated by the USDA Forest Service; however,
product users must comply with Federal, State, and
local fire prevention regulations. Check with appropriate
authorities. Contact customer service to purchase a
replacement spark arrestor.
 Inspect the spark arrestor for breaks or holes. Replace if
necessary.
 Use a brush to remove carbon deposits from the spark
arrestor screen as needed.
MAINTENANCE
DRAINING FUEL TANK/CARBURETOR
See Figures 17 - 18.
To help prevent gum deposits in the fuel system, drain the
fuel from the tank and carburetor before storing.
DRAINING THE FUEL TANK
 Turn the fuel valve to the OFF position.
 Remove the fuel line from the petcock by squeezing the
ends of the retaining clip and sliding the fuel line off.
 Install one end of a drain line over the petcock, and place
the other end in a fuel container large enough to catch
the fuel being drained from the tank.
 Turn the fuel valve to the ON position.
 When the fuel has drained from the tank, close the fuel
valve and reinstall fuel line securely on petcock.
DRAINING THE CARBURETOR
 Turn the fuel valve to the OFF position.
 Position a suitable container under the carburetor drain
screw to catch fuel; loosen the screw.
 Allow fuel to drain completely into container.
 Retighten drain screw.
NOTE: Consult hazardous waste management guidelines in
your area for the proper way to dispose of used fuel.
TRANSPORTING
 Turn the fuel valve to the OFF position.
 Allow 30 minutes of "cool down" time before transporting
the machine. Make sure engine and exhaust of unit are
cool.
 Empty the fuel tank.
 Do not drop or strike unit or place under heavy objects.
 If transporting in a vehicle, drain the fuel tank and securely
restrain the generator.