CONNECTIONS AND SIGNAGE

e1
e2
Connectors
a) System connection terminals
a1)
B, B (INPUT/ OUTPUT):
the power from either of its B B terminals (INPUT) using the other B B as bus output (OUTPUT).
a2)
B1, B1 - B2, B2 - B3, B3 - ........ - B10, B10:
you can connect a maximum of 1 terminal to each of the 10 outputs.
Status LED for each output: FIXED RED if there is a short circuit problem at the output, voltage
below 15 Vcc or overconsumption (peak consumption greater than 2 A).
b) PGM:
programming button.
c) DL (green):
power supply LED and operating modes.

OPERATING MODES

Switched off
Rapid flashing
Switched on
Slow blinking
1 flash every 3 seconds
Double flashing
d) SW SWITCH:
switch for selecting the adaptation of the line.
e) DIPSWITCHES:
to assign the DIRECTION TABLE to the decoder outputs and set the programming mode.
e1)
BLOCK ADDRESS:
• To assign the address of the Block in sequential mode.
• Dip 8 ON + DECODER DIP 8 ON: it activates the window for programming in direct mode.
• Dip 8 OFF: it deactivates the window for programming in direct mode.
e2)
DECODER ADDRESS:
• To assign the decoder output address in sequential programming.
• Dip 8 ON: it activates the direct mode, enables direct programming mode. Leave ON if this
mode has been used.
e3)
OFFSET DIR.:
OFFSET +1].
f) Silk-screen printing Box to record the addresses of each output.
The device you have purchased is identified under Directive 2012/19/EU on waste electrical and electronic
equipment. More info:
a1
d
e3
c
b
a1
terminals connecting the bus of the input/output riser. The decoder takes
DL
Not power or power < 17 Vdc
Not programmed
Standby or parameter synchronization
Receiving commands by the bus or Active communication channel
Remote address programming
Unlocking the installer menu or valid address reception in direct mode
to make the address of output 1 of the decoder start from [number chosen at
www.fermax.com.
a2
a2
connection terminals to connect home terminals.
DECODER/AISLADOR DUOX PLUS 10S