The intensity of the mist
is too low.
Strange noises during
operation
Mist is spraying out of
the area around the
nozzles
Air purifier is not
working.
Loud operating noise.
Mineral
Clean the converter.
concentration in the
basin is too high.
Water in the tank is
Clean the water tank and fill it
dirty because the
with clean water.
water has been in
the tank too long.
Vibrations in water
Fill the water tank.
tank because the
water level it too
low.
The machine is on
Set the device on a stable,
an unstable surface.
level surface.
There are gaps
Remove the nozzles and clean
between the
them with a damp cloth. Then
housing around the
reattach again.
nozzles and the top
of the water tank.
The device is not
Check the power supply of
connected to the
the socket and whether the
electrical socket.
plug is correctly plugged into
the socket.
The manual control
Contact a technician to have
has a malfunction.
the device repaired.
High degree of
Dehumidify the air using an
humidity in the
air dehumidifier.
room.
The filter is dirty.
Replace the filter with a new
one.