Malfunction disposals
Please check each item first before applying for maintenance:
Malfunction
Appliance does not
work.
Small dehumidifying
capacity.
Loud noises occur.
The unit stops during
the dehumidifying
process.
Clothes do not dry
fast
Possible causes
The power plug is not
properly inserted.
The water tank is full.
The water tank is not
properly placed.
The filter is too dirty.
The air inlet and
outlet are blocked.
The unit is not
properly placed.
The room
temperature may be
too high or low.
The room
temperature is very
low.
14
Solution
Ensure the appliance
is properly plugged in.
Empty the tank.
Ensure the tank is
properly placed.
Clean the filter.
Remove whatever is
blocking the inlet or
outlet.
Ensure the unit is on
a smooth and stable
surface.
The dehumidifier may
start automatically
when room
temperature returns
within the working
scope of the appliance.
Clothes will dry slow
when room
temperature is low.