INSTALLATION

Typical Installation

INSTALLATION
Typical Installation
Sea water outlet
Waterline
Seacock

Physical Installation

NOTE: This pump can be used inline or submerged. It is not self-priming and must be located
below the waterline. Seawater enters low and exits high.
1. Connect the strainer to the pump inlet. Refer to
• Ensure accessibility for future maintenance.
• Both pump and strainer must be mounted within 2 ft of the through-hull.
IMPORTANT: Do not connect the pump to the engine water cooling intake as this can cause the
engine to run dry.
2. Connect the seacock and strainer. Refer to
• Secure every connection with stainless steel clamps.
NOTE: The through-hull and seacock must be installed at least 8-12" below the water line.
3. Connect the pump discharge to the air conditioner. Refer to
• This pump is ignition-protected and must be within 10 ft of the air conditioner.
IMPORTANT: Do not cut hose until it is positioned in its final location.
4. Attach the bracket to the pump and mount the assembly horizontally in a stable, flat place in the
bilge.
• For power boats: ensure the pump always sits below the water line, even during hydroplaning.
• For sail boats: mount the pump close to the centerline to avoid losing water intake when heeling.
NOTE: The discharge must always sit above the inlet.
NOTE: Always orient the volute so that the inlet remains closest to the strainer and the discharge
closest to the A/C.
5. Position the through-hull water return line as close to the pump as possible and 4-8" above the
water.