Descargar Imprimir esta página

Faber BLACK TIE BRS BK A80 Manual De Instrucciones página 9

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 39
• Open the doors/the door (See section Open Panels).
• Remove the Metal grease filters using the handles provided.
• Adjust the two screws Vr, in the brackets 11a, so that they are
at the start of their travel.
• Hook the hood body to the two brackets 11a.
• From the inside of the hood body, turn screws Vr to level the
hood body itself.
• Fasten the safety screw 12a.
• Close the doors/the door again.
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert the
reducer flange 9 on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps (not
supplied).
• Remove possible charcoal filters.
RECIRCULATION VERSION AIR OUTLET
To install the Recirculation Version of the hood, the optional
Activated charcoal cartridge kit must be purchased.
• Screw the filter cover onto the air outlet, using four screws 12c
(2.9 x 12.5).
• Fix the directional grille 8 on the recirculation air outlet using
the 2 screws 12d (2,9 x 9,5) provided.
EN
Fitting the hood body
Connections
11a
Vr
12a
ø 120
ø 150
9
12d
8
12c
16
9
9

Publicidad

loading