DIGITAL VIDEO RECORDER
Note
Note
The following table shows how long it would take to fill up an 80GB HDD for each field
rate.
(Recording time for each field rate may slightly vary depending on the type of input
video singal.)
VERY HIGH
Picture Rate
80GB
60.0 FPS
11 H
30.0 FPS
22 H
15.0 FPS
44 H
10.0 FPS
65 H
NTSC
7.5 FPS
87 H
5.0 FPS
131 H
2.5 FPS
261 H
1.0 FPS
654 H
0.5 FPS
1,307 H
50.0 FPS
13 H
25.0 FPS
26 H
12.5 FPS
52 H
8.3 FPS
78 H
PAL
6.3 FPS
105 H
5.0 FPS
131 H
2.5 FPS
261 H
1.0 FPS
654 H
0.5 FPS
1,307 H
4-9
All manuals and user guides at all-guides.com
Time-Lapse Mode
HIGH
NORMAL
LOW
80GB
80GB
80GB
13 H
19 H
25 H
26 H
37 H
49 H
53 H
74 H
99 H
79 H
111 H
148 H
106 H
148 H
198 H
159 H
222 H
296 H
317 H
444 H
593 H
794 H
1,111 H
1,481 H
1,587H
2,222 H
2,963 H
19 H
27 H
36 H
38 H
53 H
71 H
76 H
107 H
142 H
114 H
160 H
213 H
152 H
213 H
284 H
190 H
267 H
356 H
381 H
533 H
711 H
952 H
1,333 H
1,778 H
1,905 H
2,667 H
3,556 H
4
Alarm Record Setup
The following illustrates the intial setting of the ALARM RECORD SETUP menu.
ALARM RECORD SETUP
ALARM SIGNAL DETECTION
ALARM SIGNAL POLARITY
ALARM BUZZER
MAIN ALARM TIME
PRE ALARM TIME LIMIT
POST ALARM TIME LIMIT
MAIN ALARM PICTURE RATE
MOTION DETECTION
SET AREA & SENSITIVITY
MOVE=[ /
ALARM SIGNAL DETECTION
You shall select ON to start recording in the event of alarming and select OFF to prevent
recording in the event of alarming. If you set the ALARM SIGNAL DETECTION to ON
and exit the menu, the system will begin recording whenever alarm occurs. To force stop the
recording during the alarm recording, press and hold the STOP( ) button for 3 seconds. Then,
the recording by the current alarm will be stoppted, and the alarm recording will not be per-
formed for the next 5 seconds even if alarm occurs. To completely stop the alarm recording,
go into the menu within that 5 seconds to set the ALARM SIGNAL DETECTION to OFF.
If no action is performed by the user for 5 seconds, the system returns to the alarm recording
mode. [ON/OFF]
ALARM SIGNAL POLARITY
Set to N. C. (Normally Close) when the alarm input is Active High, and set to N.O.(Normally
Open) when the alarm input is Active Low. [N.C./N.O.]
ALARM BUZZER
Set to ON to have the system activate the Buzzer when a motion is deteced in the input
video or when alarm occurs, or set to OFF to keep the Buzzer inactive. [ON/OFF]
MAIN ALARM TIME
Set the duration for which alarm recording is to be performed when a motion is detected in the
input video or when alarm occurs. The value can be set from 0 seconds to 5 minutes when you
set to OFF. If you set to AUTO, the alarm recording is performed only during when the alarm
signal is Active.
[5MINUTE/4MINUTE/3MINUTE/2MINUTE/1MINUTE/30SECOND/20SECOND/
10SECOND/AUTO/OFF]
OFF
N.O.
ON
10 SECOND
2 SECOND
OFF
30.0 FPS
OFF
❷
/
➛
/
❿
] SELECT=[
] EXIT=[MENU]
4-10