Descargar Imprimir esta página

Technical Information; Installation Considerations - Hansgrohe Vernis Blend 71502001 Instrucciones De Montaje / Manejo / Garantía

Publicidad

English

Technical Information

Water pressure
Recommended
Maximum
Hot water temp.
Recommended
Maximum
Max. flow rate
0.2 gallons (0.75 liter) per cycle**
Hole size in mounting surface
Max. depth of mounting surface
Automatic shutoff

Installation Considerations

• For best results, Hansgrohe recommends that this
unit be installed by a licensed, professional plumber.
• Please read over these instructions thoroughly
before beginning installation. Make sure that you
have all tools and supplies needed to complete the
installation.
• Keep this booklet and the receipt (or other proof
of date and place of purchase) for this product in
a safe place. The receipt is required should it be
necessary to request warranty parts.
• Flush the hot and cold supplies thoroughly before
installing the faucet. Damage to the faucet caused
by debris is not covered under the warranty.
• The hot and cold supplies should be of equal
pressure.
• 71501001, 71502001: The faucet should not be
used with a continuous flow water heater.
• Strong light sources should not shine directly on the
sensor window of the faucet.
2
15 - 75 PSI (0.1 - 0.5 MPa)
116 PSI (0.8 MPa)
120°-140° F (48° - 60° C)*
140°F (60° C)*
1.2 GPM (4.5 L/min)
1⅜" (35 mm)
1⅝" (40 mm)
after 10 seconds***
Battery
Power Supply
*
Please know and follow all applicable local plumbing
codes when setting the temperature on the water heater.
** 10 second cycle time / This is the maximum amount of
time the faucet will run while a hand is within range of
the sensor.
***10 Second Default (see page 18)
• The faucet should only be used with the battery
pack supplied by Hansgrohe. Do not attempt to use
any other battery pack.
• The faucet incorporates automatic range adjustment
-- the sensor automatically adjusts itself to local
conditions (lavatory, brightness, etc.)
• The distance between the switch on/off point
to the faucet is approx. 6¼" - 8" under normal
conditions. The detection area may be less for dark,
non-reflective objects, or greater for bright, highly
reflective objects.
• Drops of water or condensation on the sensor
window may cause the faucet to run.
CR-P2 / 6 V Lithium
120 Volt / 6 Volt Transformer

Publicidad