Descargar Imprimir esta página

Turning Off; Ac Connections - EcoFlow EFG100 Manual Del Usuario

Publicidad

Idiomas disponibles

Idiomas disponibles

2.4.2 Turning off

To turn the engine off in an emergency, turn the engine switch to the "OFF" position. In any other
circumstances, please follow the below steps.
1. Switch off all electrical equipment and disconnect them from the generator.
2. There are four methods to turn off the generator:
a) Using the Engine Switch: Turn the Engine Switch to "OFF" to turn off the generator.
b) Using the Electric Start button: Press and hold the Electric Start button for 2 seconds to stop the
engine.
c) Automatic shutdown: If the AC Power Button is turned off, this generator will auomatically stop
when the DC charging is completed. Refer to 2.4.4.
Tips: When the AC Power Button and DC output are turned off, it will automatically stop after 10mins
to save fuel.
d) APP shutdown, refer to 2.4.5.
3. Wait until the generator is completely cooled down, then turn the Engine Switch and the fuel cap
breather valve knob to "OFF".

2.4.3 AC Connections

1. Start the generator.
2. Insert the plug into the AC Output Socket and check that the on-screen AC output port icon is illuminated.
3. Switch on the electrical equipment.
Tips: During the operation of the generator set, the AC output can be turned on and off through the AC
switch. If the generator supplies power to multiple loads or electrical equipment, please start electrical
equipment in descending order, according to the size of the load.
Switch off all electrical equipment before inserting plugs.
Warning
Caution
Make sure that all electrical equipment including wires and plugs are in good condition before being
connected to the generator, and confirm that all loads carried by the generator are within the rated load
range and that the load current is within the rated current range.
Tips: Make sure that the generator is grounded. If any electrical equipment needs to be grounded, the
generator must also be grounded.