Clearance requirement
This clearance requirement is applicable for dryers only.
NOTE
• For washer's clearance requirement, see the washer's user manual.
• If the washer and dryer have different clearance requirements, use the one with the larger value.
Alcove or closet installations
WARNING
• The dryer must be exhausted to the outside to reduce the risk of fire when installed in an alcove or
closet.
• No other fuel-burning appliance should be installed in the same closet as the dryer.
• Place the dryer at least 18 in. (460 mm) above the floor for garage installation.
Minimum clearance for stable operation:
Sides
1 in. (25 mm)
If both the washer and a dryer are installed in the same location, the front of the alcove or closet must have
two unobstructed air openings for a combined minimum total area of 72 in.
Undercounter installation
A
B
DV6900B_SimpleUX_WEB_Heatpump_EN.indd 15
Top
1 in. (25 mm)
C
Rear
2 in. (50 mm)
(465 cm
2
A
34.4 in. (875 mm)
B
1 in. (25 mm)
C
1 in. (25 mm)
Front
1 in. (25 mm)
).
2
English 15