This product contains no serviceable parts.
GENERAL MAINTENANCE
Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and may be damaged by their use. Use
clean cloths to remove dirt, dust, oil, grease, etc.
WARNING:
Do not at any time let brake fluids, gasoline, petroleum-
based products, penetrating oils, etc., come in contact
with plastic parts. Chemicals can damage, weaken or
destroy plastic which could result in serious personal
injury.
REMOVING THE ROLLER BRUSH FOR
CLEANING
See Figure 10, page 10.
The roller brush is located inside the floor nozzle assembly.
The floor nozzle assembly has a tool-free end cap, allowing
the roller brush to be easily removed for cleaning.
To remove:
 Insert a coin into the slot on the end of the roller brush.
Rotate the end cap approximately 1/4 in. counterclockwise
to unlock the roller brush.
 Slide the brush to release the cap and pull the brush from
the floor nozzle assembly.
NOTE: Use scissors to remove any threads or hair
wrapped around the roller brush using the scissor
grooves.
To reattach:
 Insert the roller brush into the floor nozzle assembly.
NOTE: ILLUSTRATIONS START ON PAGE 8 AFTER

MAINTENANCE

FRENCH AND SPANISH LANGUAGE SECTIONS.
 Align the tabs on the cap to the notches on the floor
nozzle assembly and firmly press the cap into place.
NOTE: Make sure the opposite end of the roller brush is
aligned to the drive spindle when pressing the cap into
the assembly housing.
 Turn the end cap 1/4 in. clockwise with coin to lock into
place.
CLEANING/REPLACING THE FILTER
See Figure 11, page 10.
 Remove the battery pack and the dust bowl.
 Remove the filter assembly by pulling it out of the dust
bowl.
 Shake or lightly brush any dust or dirt off the filter
assembly.
 Remove the filter by lifting away from the assembly. The
filter may be rinsed if necessary.
 Empty the dust bowl; wash if necessary. Before reattach-
ing to the stick vac, make sure all pieces are completely
dry.
 Reinsert the filter into the filter assembly.
 Install the filter assembly into the dust bowl.
 Position the two sections as shown.
 Reattach the dust bowl by aligning the slot on the bottom
of dust bowl with the tab on the bottom of motor housing.
NOTE: Make sure tab and slot are aligned correctly before
securing the dust bowl.
 Snap the two sections together.
When purchasing a replacement filter assembly, request
recommended part number 903623004.