Descargar Imprimir esta página

AKO-Agrartechnik Duo Power Xi 8000 Manual De Instrucciones página 5

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 7
Device-specific operating instructions
1
2
4
3
7
5
a.) Montage
The device must always be vertically suspended, operated with the connections downwards and protected from rain and sun if possible, see picture
above on the left. For wall mounting, it must be mounted on a fireproof wall. For outdoor mounting, a galvanized metal box can be used as an accessory
(Item No.:44656), it protects the device and at the same time absorbs the battery.
b.) Functional description of the device
Device WITHOUT fence and earth. When connecting the 12V battery, pay attention to correct polarity (red + and black -). If all fence LEDs (1) blink in
stage II, the device is functional. If these do not flash, please check the BATTERY for voltage, see table (c.). If the battery lamp (2) flashes red, the voltage
of the 12V battery must be checked. If the fence light (1) does not flash, check the polarity of the 12V connection cable to the battery or have the device
checked by a specialist! For 230V operation with mains adapter (item number 371023 not included), remove 12V cable and screw on mains adapter"
(5).The device can optionally also be connected to a 230V AND 12V battery at the same time (back-up function). For this purpose, the 12V battery is
connected via the connection (5) and a separate 230V adapter (item number 371012 not included) is connected to the connection (4). The AN 4000 can
optionally be supported via a 25W solar module (item number 375256). Connection to socket (4). Solar module support for the AN 6000 is provided with
45W solar module (item 375459). Here the connection is made directly to the 12V battery.
c.) Functional description with CONNECTED fence (fence + earth)
ZAUN‐LED (1) KV 
 
 
 
 
 
 
 
 
 
Alarm - TONE:
The unit goes into alarm (one pulse is above 1000 OHM next pulse is below 400 OHM). (e.g. human touch).
If the increased load remains after 6 pulses, the alarm horn goes on and the pulse time is extended to 3sec.
After 15min. without change of load, the alarm mode stops, the unit increases the energy and sees the new fence level as NORMAL.
Should the fence light (1) faster than approx. 1x blinking per second, the device must be switched off immediately and must be professionally checked
before re-commissioning.
!!! Attention: Earth rods are not included (use at least 3 earth rods with about 1m length) !!!
The proper functioning of the electric fence system must be checked daily at least once by a voltage measurement on the fence. The voltage in normal
ground at each point of the fence shall be at least 2000 V (for cattle at least 3000v, for sheep, goats, poultry and wild animals at least 4000v). For dry
soils we recommend this min. Voltages increase by 1000V each.
The electric fence must be checked daily, in particular the output voltage and - for battery devices - the battery voltage. Accumulators or. Batteries
must be recharged or replaced if necessary.
The proper mechanical condition of the fence must be checked regularly (for example weekly).
This device is covered by a 3-year warranty, according to our warranty conditions!
Safety instructions, grounding, commissioning, battery and battery maintenance, warranty conditions and possible sources of error can be
found in the general information!
SERVICE Addresses:
Please contact your specialist dealer
Normal operation with 12V wet
battery,
(Optionally, the device can also
with a 230 - power adapter
be operated!
The electric fence may (in the barn)  
not be used as an animal trainer! 
9KV = 9000V
8KV = 8000V
7KV = 7000V 
6KV = 6000V
5KV = 5000V
4KV = 4000V
3KV = 3000V min. voltage
2KV = 2000V
< 2KV = 2000V
1
)
2
3
4
6
5
6
7
Battery voltage in V 
> 12,4 
12,4 - 12,0 
BATTERY LED (2) ‐ Volt 
‐‐ 
Every 3 tacts 
Every 2 tacts 
Every tact 
Flashes only the BATTERY LED without the fence LED
and the device gives no pulse to the fence, the device is
in deep charge mode and has switched off!!!
If the RED BATTERY LED flashes with each clock, the
BATTERY should be replaced / charged!!!
3
-EN-
Indicator lamps
Fence tension
Indicator lamp
12V battery
2-step switch
0 = OFF
I = approximately reduced current
consumption
Output energy ( = 50%)
II = maximum output energy
Current consumption ( = 100%)
Socket
+ protective cap
- Solar
- BACKUP power adapter (item
372012)
12V - connection
(also for power adapter 230V - item 372023)
Earth connection
Fence connection
Open circuit voltage in
10100 
8700 
>12V 
12,0 – 11,6V 
11,6 – 11,4V 
11,4 – 11,2V 
Version : 2022.1

Publicidad

loading

Productos relacionados para AKO-Agrartechnik Duo Power Xi 8000

Este manual también es adecuado para:

Ba-1384