FUNCTION OVERVIEW
CHARGING MODES
The TORNADO 30000 offers 12 charging modes: 12V/30A
NORM, 12V/30A LITHIUM, 12V REPAIR, 24V/15A NORM,
24V/15A COLD AGM, 24V/15A LITHIUM, 24V REPAIR, 6V/15A
NORM, 6V REPAIR, 12V/30A SUPPLY, 24V/15A SUPPLY,
12V/10A NORM. Understanding the differences and
purposes of each charging mode is very important. Read
below a brief description to help with comprehension:
MODE
MAX CHARGING VOLTAGE
12V/30A
NORM
12V/30A
LITHIUM
12V REPAIR
24V/15A
NORM
24V/15A
COLD AGM
24V/15A
LITHIUM
24V REPAIR
14.5V
14.3V
15.5V
29V
29.5V
28.6V
31V
EXPLANATION
Charge 12V Wet, Gel, MF,
Cal, EFB and AGM batteries
through 9-step smart
charging.
Charge 12V li-ion batteries.
Repair old or sulfated 12V
batteries through small
current and pulse current.
Charge 24V Wet, Gel, MF,
Cal, EFB and AGM batteries
through 9-step smart
charging.
Charge 24V WET, GEL, MF,
CAL, EFB, AGM batteries with
an ambient temperature
below 32ºF (0ºC).
Charge 24V li-ion batteries.
Repair old or sulfated 24V
batteries through small
current and pulse current.