Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

Always check the presence of the SEAL GASKET particular [H], fixed on
the pressure regulator connection.
When proceeding to connection, according to UNI-CIG 7131, of B type
fixed pressure regulator 30mbar, compliant to UNI-CIG 7141, to
the cylinder, avoid bending and make bottlenecks on the rubber tube.
Ventilation of rooms
USE ONLY IN WELL-VENTILATED ROOMS, in rooms where the stove is used,
adequate ventilation must be provided. This ensures the removal of the exhaust combustion products and guarantees the
exchange of air.
OPERATING INSTRUCTIONS
8) Open the gas cylinder valve.
9) STARTING FROM POSITION "● " press the adjustment knob for about 10 seconds, and then continuing to press it, crush
one or more times the piezo igniter until the ignition of the pilot flame and the central plate.
10)
continue to hold the knob pressed for 20 seconds, to allow the thermocouple to heat,
11)
power level according to the following instruction:
(Small flame) minimum flow, (medium flame) average flow, (large flame) maximum power.
12)
release the knob if the pilot flame remains lit, the heather is regular working, if the pilot flame goes out repeat the ignition
procedure.
13)
cylinder valve.
All our heathers are equipped with a safety device (ODS) that operates automatically turning it off if the percentage of CO2
(Carbon dioxide) exceeds the legal limit.
Stuck "in the low position" the control knob, cancels the intervention of the safety devices;
Be careful to always keep the control knob from returning to "high" position of rest.
Before turning on the stove, check that the front part has not been
deformed inwards due to transport. In this case, before turning it on, it is
advisable to apply light pressure to the sides(sides arrow) of the front
panel to reposition it correctly.
Sprinkle with a soft wet cloth only when switched off, cold and unplugged.
✓ Do not use solvents or abrasive detergents.
Check that the dust does not obstruct the air openings inlet or outlet.
To clean use a vacuum cleaner.
Cover and store the appliance in a dry and dust-free place.
For any technical and / or maintenance problems please contact authorized dealer.
✓ Every five years should be made a maintenance check at authorized service centre

IMPORTANT

Before switching on the gas burner, read the instructions carefully.
CAUTION
MAINTENANCE
When the pilot flame has been switched on
Then rotate the knob to select the desired
Keep on the knob pressed for 20 seconds;
To turn off the heater you must close the

Publicidad

loading