Transport

Caution
Risk of injury and damage! Observe the weight
of the appliance when you transport it.
 Remove the suction pipe with the floor
nozzle from the holder. Hold the appli-
ance at the handle and at the suction
pipe to transport it.
 When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.
This appliance must only be stored in inte-
rior rooms.

Maintenance and care

Danger
First pull out the plug from the mains before
carrying out any tasks on the machine.
Exchanging the flat pleated filter
 Open filter door.
 Replace the flat pleated filter.
 Close the filter door, it must lock into
place.
Cleaning the electrodes
 Release and remove the suction head.
 Clean the electrodes with a brush.
 Insert and lock the suction head.

Troubleshooting

Danger
First pull out the plug from the mains before
carrying out any tasks on the machine.
Suction turbine does not run
 Check the receptacle and the fuse of
the power supply.
 Check the power cable, the power plug,
the electrodes and possibly the recep-
tacle of the device.
 Turn on the appliance.
16

Storage

Suction turbine turns off
 Empty the container.
Suction turbine does not start again
after the container has been
 Turn off the appliance and wait for 5
seconds, turn it on again after 5 sec-
onds.
 Clean the electrodes as well as the
space between the electrodes with a
brush.
Suction capacity decreases
 Remove blockages in the suction noz-
zle, suction tube, suction hose, or flat
pleated filter.
 Exchange the paper filter bag.
 Exchange the fleece filter bag (option).
 Ensure the filter cover properly locks
into place.
 Clean or replace the membrane filter
(special accessory) under running water.
 Replace the flat pleated filter.
 Check drain pipe for leaks.
Dust comes out while vacuuming
Illustration
 Check/correct the correct positioning of
the flat fold filter.
 Replace the flat pleated filter.
Automatic shut-off (wet vacuum
cleaning) does not react
 Clean the electrodes as well as the
space between the electrodes with a
brush.
 Continuously check the filling level in
case of non-conductive liquid.
Automatic filter cleaning is not
 Suction hose is not connected.
– 4
EN
emptied
working

Publicidad

loading

Este manual también es adecuado para:

Nt 55/1 tact te