Detector modes and LED states
Table 1: Detector modes
Mode
Power supply
Low battery
Flat battery
Starting up
Not enrolled
No communication
Operation
Walk test mode
Range test mode
Good range
Medium range
Weak range
No communication
for 15 s
No communication
for 1 min
Enrolling and deregistering
Not enrolled
Already enrolled
Continuously on
Normal blinking (1 Hz)
P/N 1078288 (ML) • REV D • ISS 11APR18
Indication details
Description
Depend on other
Battery voltage < 2.8 V.
states
PIR is functional, camera takes pictures only on command.
Battery voltage < 2.4 V.
Device locks up, no operation.
Red LED
PIR starts up in legacy mode.
continuously ON
Walk test is enabled from 1st to 5th minute after powering on.
during 1 minute
Camera functionality is disabled.
Device is ready for enrollment.
Green and red LEDs
PIR starts up in legacy mode.
alternate during
Walk test is enabled from 1st to 5th minute after powering on.
1 minute
Camera functionality is disabled.
Device is seeking for communication with the panel.
Camera is synchronizing with the expander.
Red LED is ON for
PIR functionality is enabled.
3 s to indicate motion
Continuous alarm detection without lockup.
detected
Pictures on PIR alarm and on tamper alarm.
The mode is activated from the control panel.
The device is on hold, only LED indication is functional.
The LED follows the weakest communication link of LDR and HDR.
See an appropriate wireless expander manual for details on the
communication quality.
See an appropriate wireless expander manual for details on the
communication quality.
See an appropriate wireless expander manual for details on the
communication quality.
Blinking LED color reflects the last range measured just before
communication started to fail.
Permanent loss of communication turns range testing off.
Note:
Red LED turns ON
Enrollment of a device is possible only if the system is in enrollment mode.
while enrolling for
Enrollment of a device is possible only if the device is not already enrolled.
a maximum duration
Tamper switch toggling triggers the enrollment process.
of 15 seconds,
Successful enrollment permanently associates a device with the system.
changing to green on
success.
Enrollment of a device is not possible without deregistering the device first.
Deregistering is accomplished by applying the KILL jumper (see Figure 10,
item 1) and cycling power.
Successful deregistering dissociates a device from the system.