CoolAir
The distance "x" has to be measured again. This measure is needed to determine
the spacer and screw length for the fastening of the cover frame.
Example:
• Screw length = x + (23 to 27) mm:
In case "x" is 51 mm, the suitable screw length is 75 mm
• Spacer length = x + 9 mm:
In case "x" is 51 mm, the suitable spacer length is 60 mm
8

Configuring the system software

Before the system is first put into operation, the control unit settings can be
adjusted to suit the various installation conditions. Those adjustments must be
made by the installer (fig. 5).
Display
indication
P.01
P.02
P.05
I
NOTE
Configuration mode can still be activated if the low voltage cut-out has
switched off the system and only residual voltage is available.
8.1

Entering and exiting configuration mode

1. Press and hold the
2. Press and hold the
✔ The display shows the
✔ The parking cooler switches to configuration mode.
✔ The display shows "P.01" and the
3. Scroll through the menu by pressing the
desired menu item.
4. Press the
5. Press and hold the
EN
Parameter
Meaning
Low voltage
The battery monitor shuts down the
shut-down
system at the voltage defined here.
RTX 24 V
RTX 12 V
Unit for tempera-
The temperature can be displayed in
ture display
°C or °F.
Tilt sensor
The tilt sensor can be calibrated to a
zero setting.
button.
button for longer than 3 s.
symbol.
button to open the desired menu item.
button for longer than 3 s to exit configuration mode.
Configuring the system software
symbol flashes.
or
button to select the
Factory
setting
22.8 V
11.5 V
°C