3.2

Technical data

Nominal load according to EN 1398
Voltage supply
Motor
Power
Operating mode
max. duty cycle
Protection type
Permissible inclination of the dock leveller platform according to
EN 1398
Permissible ambient temperature during operation
Maximum permissible traversing speed
Sound pressure level L
3.2.1 Door dimensions
A
B
B H
Fig. 2: Exemplary representation, illustration may deviate from the product
OL
Overall length (NL + 330 mm)
IL (GL)
Inclination length (NL + 190 mm)
NL
Nominal length
NW
Nominal width
NL
2000
2500
2750
3000
3500
3500
NW: 2000, 2100, and 2250 for all sizes
All dimensions in mm.
These assembly, operation and maintenance instructions must be kept for the entire period of use!
pA
O L
L L
DH (BH)
600
600
600
600
600
700
80 kN
3 N~, 400 V, 50 Hz, 16 A
0.75 kW
S3
20 %
IP 65
12.5 % (7°)
−20 °C ... +40 °C
7 km/h
< 70 dB(A)
G L
N L
HL (LL)
Hinged lip length
DH (BH)
Design height
A
Upper bridging
B
Lower bridging
A (LL = 400)
360
380
390
400
280
480
N W
B (LL = 400)
300
270
270
260
310
310