ENGLISH
Battery power detection
The device features a multi-level battery guard that protects your vehicle battery from excessive discharge when the
device is connected to the built-in DC power supply. If the cooler is operated with the vehicle ignition off, the cooler
will shut off automatically when the power supply voltage drops below a set level. The cooler will turn back on once
the battery is charged to the restart voltage level. The compressor will restart automatically in a few minutes when
the voltage returns to normal values.
Note: these values are measured at the input of the control unit and / or at the DC connection.
1.
Battery protection function for the cooler with three-class battery protection function, can automatically check
the battery voltage of the vehicle, before the electricity consumption will affect the normal functions of the car.
The cool box will stop automatically to ensure that the car's battery does not run out.
(high "
2.
Method for adjusting the battery protection: read under the section "Control" how to adjust the battery
protection.
Voltage
Protection
Position
Low
Middle
High
Tip: It is recommended to set the H-class when the cool box is connected to a vehicle, otherwise the car's battery
may be too empty and affect the normal ignition of the car; When connecting the cool box to an external or backup
battery, it is recommended to set the M-mid range so that the cool box can work longer.
Error code list
E1
Battery voltage is low
E2
Fan failure
E3
Compressor start up problems
E4
Compressor running speed fails to reach the requirements
E5
The model is overheating
E6
Compressor control module fault
E7
Thermal head fault (NTC open circuit or short circuit)
Cleaning
1.
Before cleaning, remove the products from the device and remove the plug from the power supply. Only clean
with a slightly damp cloth, if necessary a non-aggressive cleaning agent can be used. After cleaning, always
dry all wet surfaces with a dry cloth.
2.
Never use sharp or abrasive products to clean the device.
3.
Defrost the cool box: frost can settle on the evaporator or inside of the cool box due to humidity, this can
reduce the cooling capacity. The cool box must be defrosted in time:
1. Take the products out of the cool box
2. Switch off the device
3. Open the lid
4. Sweep up the melt water or drain the melt water through the plug
") (middle "
") (low "
Display
1 bar
2 bars
3 bars
")
12V
CUT OFF (V)
CUT IN (V)
9.6V
10.9V
10.4V
11.7V
11.1V
12.4V
24V
CUT OFF (V)
CUT IN (V)
21.3V
22.7V
22.8V
24.2V
24.3V
25.7V

Publicidad