Descargar Imprimir esta página

Novellini EON A-2P-GF-R Manual Del Usuario página 7

Ocultar thumbs Ver también para EON A-2P-GF-R:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 12
ENGLISH
1) Check that the mains electrical equipment connected to cubicle conforms
to current electrical standards and regulations and is fitted with a fully
efficient earth connection.
2) Current electrical regulations forbid the installation of any electrical
equipment (e.g. plugs, switches) inside a radius of 60 cm from the cubicle
and at a height of 225 cm.
3) Check that rating of the mains power supply line matches the absorbed
power specified for the cubicle (see Technical specifications).
4) The electrical connection between the cubicle and the mains must be
protected against water spray and must have a protection rating of IP55
or higher.
5) The electrical equipment upstream from the cubicle must be fitted with
an omnipolare 30 mA switched circuit breaker with a minimum contact
opening of 3 mm, which conforms to current electrical regulations.
6) The manufacturer declines all responsibility for injury or damage resulting
from failure to observe these instructions.
-7-

Publicidad

loading