• Do not remove the hose while inflating. High air pressure may be harmful to people nearby.
• Operate the pump for a maximum of 20 minutes continuously and then allow to cool for 30 minutes before using again
to prevent overheating.
• Do not expose the pump to rain or water.
• The inflation hose should never be pointed at the face or body while the pump is in use.
• Do not leave the pump unsupervised while inflating or deflating.
• Comply with local disposal regulations for electrical products.
2. INFLATION
• Locate the end of the hose into the nozzle that matches the valve fitting on
the item to be inflated. Turn clockwise to lock into position on the air hose.
• Connect the hose and nozzle to the valve, and lock
in position by turning clockwise (FIG 1).
• Connect the opposite end of the hose with the nut to the air
pump's inflation port and lock it by turning clockwise. (FIG 2).
• Insert the cigarette lighter power connection to a 12 volt power source.
• Press the unit button to select pressure display in PSI or BAR.
• Press the Pressure Increase Button (+) or the Pressure Decrease Button
(-) to set the inflation pressure required from 0 to 20PSI.
• Short press the Power Button to begin inflating.
• When the pressure value reaches 1PSI, the pump automatically converts to high-
pressure inflation until it reaches the set pressure value.
• For immediate high pressure inflation long press (3 seconds) the Power Button.
• During inflation, the target pressure value can be increased or decreased by pressing the
Increase (+) or Decrease (-) button. The pressure unit button PSI/BAR can be pressed to
change the unit, and inflation can be stopped by pressing the Power Button.
• When the pressure reaches the set value, the air pump will automatically stop inflation.
• After inflating, remove the power cord from the 12V DC socket being used.
• When not in use, disconnect the hose from the air pump.
• In rare circumstances geographical and environmental influences can result in inconsistent pressure
readings. Press and hold the PSI/BAR unit shift button for 5 seconds to recalibrate the pump.
NOTE
1.The air pump has a pressure value memory. Unless manually changed the target pressure value will display by default
the same as during last use.
2.When the air pump is powered on and is not operated for 2 minutes, it will enter standby mode. Press any button to exit
standby and operate the pump