Descargar Imprimir esta página

Technical Features; Setting And Use Of Apparate - MZ electronic NAUTI800 Instrucciones De Uso

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Technical features

WARNING: USE ONLY WITH DIRECT CURRENT!
✓ Supply voltage: from 10 to 30 VCC
✓ Remote control connected with 3-wires cable
✓ Output voltage : equal to the battery supply voltage
✓ DON'T USE WITH A LOAD GREATER THAN 3 AMPS.
✓ Cable can be extended up to 3 m.
✓ Ergonomic case moulded in self-extinguishing polyester resin, shockproof and marine corrosion
resistant
✓ Watertight protection: IP56 remote control – IP68 plug and socket.
✓ Decoder Watertight protection – IP 55
✓ Remote control dimensions: 140x60x20 mm.
✓ Decoder dimensions: 190x140x70 mm.
Installation
ALWAYS DISCONNECT THE BATTERY BEFORE INSTALLATION!
✓ Mount the decoder in a dry and repaired place to prevent water infiltration.
✓ Make fixing holes and mount the socket with the supplied screws, if possible in a dry place.
✓ Connect the device by following the electrical drawing in this manual.
✓ Use wires with cross section bigger than 1mm
✓ Terminal box "A" : connect the decoder socket with 3 poles to the contacts n° 1,2,3
✓ Terminal box "B": Connect the oil pump relay to the terminals 3,4 (this output is activated with a
key pressure and deactivated at key release.) Connect the battery supply voltage to contacts n° 1,2
according to the indicated polarity. The electrical board is protected by a fuse (4A)
✓ Terminal box "C": Connect relays or electrovalves to terminals from 1 to 10. Warning: the
output voltage is positive and equal to the battery voltage. The terminals from 5 to 10 are used
for the common contact of relays and must be connected to the negative battery voltage.

Setting and Use of apparate

DON'T OPEN REMOTE CONTROL AND PLUG OR DECODER TO WARRANTY WATERTIGHT
PROTECTION.
1. Connect the plug into the socket and turn its locking ring clockwise until its stop.
2. Switch on electrical power and be sure about the correspondence between commands and
buttons.
3. Push the ON button to enable the remote control.
4. Commands are disabled 2.5 min. from the last command. Repeat from point n. 3 to restart the
operations with remote control.
5. Push the button of to the required command and check the exact correspondence between
commands and buttons as indicated on the manual. The oil pump is activated every time a key
button is pressed.
6. The output is interrupted every time the relative button is released and the oil pump goes off.
7. The remote control can activate only one output at a time.
Nauti800
2
3
English
Rev 2021

Publicidad

loading