FUNCTIONS FOR UP-AND-OVER DOOR OPENING - Dip Switch B n°1=ON
Description
with one pulse from the open command the door opens and stops in Dwell
mode for the time pre-set on the
closes
with one pulse from the open command the door opens and stays
stopped. To close the door, a close pulse is needed.
(DIP-A No. 3 = ON
This function allows automatic re-closing of the door 3 seconds after passing between
the photocells.
For the
control ( evice for afety uto-test) it is necessary
to connect
and to select
X and ELPRO XE will check that all the connected photocell
devices are cleared from obstacles and properly working before
starting any door movements, otherwise the door is not started.
The open/close operations are achieved by " holding on a command switched" (the relay is
not self-retaining) and consequently the user must be actively present during all automation
movements until the push-button or the key-switch is released.
This is a function for intense use with frequent inversions of direction: when this function is
enabled it takes into account the remaining motor run time when there is an inversion of
direction or passage between the photocells.
Connection: connect the Clock NO contact in parallel
with OPEN terminal No. 4 and COMMON No. 3, activating
automatic re-closure with Dip-Switch No. 3=ON.
Operation: program the opening time on the clock.
When this present time comes up the gate will open and
remain open (the flashing light turns off) and will not
accept any other command (not even radio
commands) until the time set on the clock expires. When
this time expires the gate automatically closes after the
pause time.
XE
UNIVERSAL ELECTRONIC CONTROL BOXES
230V 50/60Hz SINGLE-PHASE
. When this time expires the door automatically
in opening and dwell cycles
to this output
if this function is enabled, ELPRO
3 4
Dip-Switches and LED signals of the various functions
DIP-SWITCH-A N°3:
ON: Closes automatically
OFF: Semi-automatic
3
DIP-SWITCH-A N°11:
ON: Automatic re-closure after passage
between the pair of photocell after 3 seconds
11
OFF: No automatic re-closure
DIP-SWITCH-B N°4:
15
16
ON: Activates the DSA safety control
OFF: Deactivates the DSA safety control
4
for
photocell TX assigned
to the
DIP-SWITCH-B N°2:
ON: Activates the deadman mode
OFF: Deactivates the deadman mode
2
DIP-SWITCH-A N°12:
ON: Run Time memory enabled
OFF: No memory enabled
12
DIP-SWITCH-A N°3:
External clock
ON: Closes automatically
3
NO
meccanica
FADINI
: adjusts pause time for
Automatic mode from 1s up to 220 s
page 21