Technical specifications
Dimensions
BE1441: 70 140 mm, 2.7 5.5" (Ø H)
BE1442: 78 155 mm, 3.1 6.1" (Ø H)
Weight
308 g, 10.8 oz. (both models)
Mains power
7.5 V DC / 1500 mA
Only use the supplied power adapter. This product is also designed
for IT power distribution systems with phase to phase voltage of up
to 230V. The outlet shall be installed near the equipment and shall be
easily accessible.
Power consumption
Active: 750 mA, idle position: 8 mA
BE1442 battery backup
Battery type: 4 1.2 V Lexel 600/900 mAh
Operating time: ~ 48 h when fully charged
Connections
2.5 mm external trigger jack
3.5 mm bed shaker outlet, vibration power:
2.0 – 4.0 VDC (max. 500 mA)
RJ–11 telephone modular jack, 26 – 120 V RMS, 15 – 100 Hz
Barrel jack for the external power adapter
Programming pin for service purposes. Output: 3.3 V/max. 150mA.
Flash
Built-in ~30 Candela Xenon light
Warning!
Flashes can cause epileptic seizures
Radio frequency
868.30 MHz
Coverage
50 – 250 m, 55 – 273 yards depending on the characteristics of the
building.
In the box
BE1441 Visit flash receiver or
BE1442 Visit flash receiver with battery backup
7.5 V DC / 1500 mA power adapter
4 1.2 V AAA NiMH batteries (BE1442 model only)
Compliance information
Hereby Bellman & Symfon declares that, in Europe, this product is in compliance with the essential
requirements of the Medical Device Regulation EU 2017/745 as well as the directives and regula-
tions listed below. The full text of the declaration of conformity can be obtained from Bellman &
Symfon or your local Bellman & Symfon representative. Visit
Radio Equipment Directive (RED)
Medical Device Regulation (MDR)
Restriction of Hazardous Substances Directive
26
bellman.com
for contact information.
REACH Regulation
EC Battery Directive
Waste Electrical & Electronic Equipment, WEEE
Troubleshooting
If
Try this
The receiver seems to be
Check that the power supply is connected correctly.
turned off
Charge the backup batteries for at least 24 hours (BE1442 only).
The power LED blinks in
The backup batteries are nearly depleted and the power supply
red
is disconnected. Connect the power supply and charge the
batteries for at least 24 hours.
The power LED blinks in
The receiver detects no backup batteries. Pull the battery tab,
green
see
Getting
The receiver does not re-
Check the transmitter batteries and connections.
spond when a transmitter is
Move it closer to the transmitter to make sure it's within range.
activated, but works when I
Check that the receiver is set to the same radio key as the other
use the test button
units in the Visit system, see
The receiver is activated for
There is probably another Visit system installed nearby that
no apparent reason
triggers your system. Change the radio key on all units, see
Changing the radio
The flash is too bright
Redirect the light by rotating the top or use a silicone slip-on
top accessory to dim the light.
started.
Changing the radio
key.
key.
EN