2. How to adjust airflow
Slide the side airflow control valve to adjust airflow.
3. Replacing coil
a. Remove the used coil from the cartridge. Install a new coil.
b. After filling the new pod cartridge, please let the pod sit for
10 minutes to avoid coil burning.
Device Instructions
1. Turn on/Turn off
Press the fire button 5 times within 2 seconds
to turn on/off the device. The display shows
"UWELL" when power is on and the display
shows "Goodbye" when power is off.
2. Standby
The device will switch to standby mode after 8 seconds without
any operation.
3. Vaping time
The device will display the warning "OVER 8S!"
and stop output in the case of vaping for over 8
seconds.
4. Lock/Unlock
Press the fire button 2 times in a row to lock or
unlock the fire button.
5. Wattage adjustment
Press the fire button 3 times in a row, the power
display area flickers, and power adjustment mode
starts. Press or hold the fire button, output power
- 5 -