FUNCTION: Can identify day and night: The consumer can adjust working state in different
ambient light. It can work in the daytime and at night when it is adjusted on the "sun"
position (max). It can work in the ambient light less than 3LUX when it is adjusted on the
"3LUX" position (min). As for the adjustment pattern, please refer to the testing pattern.
• Photocell function: When LUX knob turned at SUN|MOON icon, the sensor will only work
as a Photocell. When ambient natural light is less than 15Lux, the sensor will work and
turn on the lamp, and when the natural light is more than 50Lux, the sensor will switch
off the lamp. • Time-Delay is added continually: When it receives the second induction
signals within the first induction, it will restart to time from the moment.
INSTALLATION ADVICE: As the detector responds to changes in temperature, avoid the
following situations: Avoid pointing the detector towards objects with highly reflective
surfaces, such as mirrors etc. Avoid mounting the detector near heat sources, such as
heating vents, air conditioning units, light etc. Avoid pointing the detector towards objects
that may move in the wind, such as curtains, tall plants etc.
Warning: Danger of death through electric shock! Must be installed by professional
electrician Disconnect power source. Cover or shied any adjacent live components. Ensure
device cannot be switched on. Check power supply is disconnected.
CONNECTION: Unload the cover near the detection window and adjust the TIME and LUX
knob. If you need detection range less then 360°, you can install the plastic cover above
the detection window. (refer to figure1). Unscrew the screw below the detection window
and unload the bottom (refer to figure). Also unscrew the two screws at the bottom and
unload the bottom into two parts. (refer to figure) • Find the wire hole at the bottom and
pass the power wire through the hole. Connect the power with the connection-wire
column according to the Connection-wire Diagram. • Fix the bottom on the selected
position with the inflated screw. • Fix the sensor at the bottom and tighten the screw.
Switch on the power and then you can test it. Note: It not only can install on the wall
directly but also can install in the inner corner or outer corner with the help of the widget
(refer to figure): Note: you can cut the plastic cover whatever shape you want and make
different detection range. (refer to figure)
CONNECTION-WIRE DIAGRAM: (See the right figure)
TEST: Turn the TIME knob anti-clockwise on the minimum (10s). Turn the LUX knob
clockwise on the maximum (sun). • Switch on the power; the sensor and its connected
lamp will have no signal at the beginning. After Warm-up 30sec, the sensor can start work
.If the sensor receives the induction signal, the lamp will turn on. While there is no another
induction signal any more, the load should stop working within 10sec±3sec and the lamp
would turn off. • Turn LUX knob anti-clockwise on the minimum (3LUX). If the ambient
light is more than 3LUX, the sensor would not work and the lamp stop working too. If the
-2-
ambient light is less than 3LUX (darkness), the sensor would work. Under no induction
signal condition, the sensor should stop working within 10sec±3sec.
• Turn LUX knob at position (MOON|SUN), the sensor will only work as a Photocell. When
ambient natural light is less than 15Lux, the sensor will work and turn on the lamp, and
when the natural light is more than 50Lux, the sensor will switch off the lamp. The sensor
will not respond to lights less than 600LUX from LED or Energy-saving lamps if ambient
natural light does not reach more than 50Lux. Note: when testing in daylight, please turn
LUX knob to (SUN) position, otherwise the sensor could not work!
SOME PROBLEM AND SOLVED WAY:
The load does not work: a. Please check if the connection of power source and load
is correct. b. Please check if the load is good. c. Please check if the settings of working
light correspond to ambient light.
The sensitivity is poor: a. Please check if any hindrance in front of the detector to affect
it to receive the signals. b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection field. d. Please check
if the installation height corresponds to the height required e. Please check if the
moving orientation is correct.
The sensor can not shut off the load automatically: a. Please check if there is continual
signal in the detection field. b. Please check if the time delay is set to the maximum
position c. Please check if the power corresponds to the instruction.
PL
Sufitowy czujnik ruchu
Produkt wyróżnia się wysoką czułością poprzez zastosowanie układu scalonego.
Łączy w sobie automatyzm, wygodę użytkowania, bezpieczeństwo, oszczędność energii
oraz praktyczne funkcje. Urządzenie to wykorzystuje promieniowanie podczerwone
emitowane przez człowieka jako sygnał do rozpoczęcia pracy w momencie gdy ktoś
znajdzie się w zasięgu detekcji.
SPECYFIKACJA:
Zasilanie: 220-240V/AC
Kąt wykrywania: 180°
Częstotliwość zasilania: 50/60Hz
Zasięg wykrywania: 12m max (<24°C)
Natężenie światła: <3-2000LUX (regul.)
Opóźnienie czasowe:
Min.10sec±3sec / Max.15min±3min
FUNKCJE: Urządzenie rozróżnia dzień i noc. Użytkownik może dostosować pracę
urządzenia w zależności od światła otoczenia. Urządzenie może pracować zarówno
MCE202
Temperatura pracy: -20/+40°C
Wilgotność pracy: <93%RH
Zużycie energii: ~0.5W
Max. obciążenie:
1200W 300W
Wysokość montażu: 1.8-2.5m
Szybkość wykrywanego ruchu: 0.6-1.5m/s
-3-

Publicidad

loading